Battery Replacement; Telephone Controller; Technical Specifications; Warranty - Aube Technologies TH141-HC-28 User Manual

Hide thumbs Also See for TH141-HC-28:
Table of Contents

Advertisement

Available languages

Available languages

Select the heating, air conditioning, or mixed mode
Use the Heat/Cool button to select one of the following modes:
Heating:
Controls the heating unit.
Air-conditioning:
Controls the air-conditioning unit.
Mixed:
The TH141 analyzes the temperature pattern and
automatically alternates between heating mode and
air-conditioning mode.
To avoid needless switching, the automatic mode change will take at
least 2 minutes if it is required by a manual setting change and at least 15
minutes if it is due to a quick temperature change.
Furthermore, to protect your heating and air-conditioning system, it is
impossible to shut down and restart the system within a period equal to
10% of the cycle.
Fan control
Use the Fan On/Auto button to force continuous air circulation (
appears) or to synchronize the fan with the heating or air-conditioning
demand ( disappears).
Please note that if you set the TH141 in Vacation mode using the
telephone controller or a house automation system, the continuous air
circulation will be automatically deactivated during your absence.

Telephone controller ( )

The TH141 incorporates a telephone controller interface which allows
you to switch from the normal operating mode to the Vacation setting
( ), and vice versa, using the telephone keypad (stationary or portable).
You can, for example, heat your country house from your office on Friday,
or your house from the airport or from your car on your way back from
vacation.
6.1
Connection to the CT240
The TH141 is designed to connect directly to
the
CT240
telephone
controller.
combination
allows
the
activation
deactivation of the Vacation mode from the
CT240 or the telephone.
Connect the CT240's terminals A and C to
the TH141's terminals X and C respectively.
You must respect the polarity.
For details on operating the telephone
controller, refer to the CT240's Instruction
Manual.
6.2
Connection to a house automation system
The Vacation setting can also be
activated from a house automation
system.
6.3
Operating the telephone interface
You can activate the Vacation setting using the Vacation button of the
telephone controller or using the telephone itself.
To activate the Vacation setting, press the Vacation button of the
CT240. The Vacation setting will be displayed on the thermostat
during 5 seconds and the
longer have access to the TH141 keypad if this function is activated
by the telephone controller.
To deactivate the function and return to the previous mode, press
the Vacation button of the telephone controller again. The red light
will go off and the
icon will disappear from the thermostat within a
maximum of 5 seconds.
To modify the Vacation setting, refer to section 2.2.
TH141-HC-28
This
and
icon will flash on the screen. You no
4.

Battery replacement

The TH141 will display an icon indicating that
the batteries must be replaced. This icon will
flash for 60 days. After this delay, the thermostat
will shut down your heating unit. During battery
replacement, the data is kept for of 15 seconds.
The time and the programs will not be lost.
After this delay, the TH141 runs a sequence of
tests and a complete reset to zero as for the
initial installation of the batteries.
Even if the thermostat indicates that the batteries are good, it is
recommended to replace them once a year.

Technical specifications

5.
Power supply:
Connection:
Maximum load:
Auxiliary input:
Number of programs:
Heating setting range:
Air-conditioning setting range: 16 °C to 40 °C (60 °F to 105 °F)
6.
Anticipation:
Regulation:
Regulation periods:

Warranty

Resideo warrants this product, excluding battery, to be free from defects in workmanship
or materials, under normal use and service, for a period of five (5) years from the date of
first purchase by the original purchaser. If at any time during the warranty period the
product is determined to be defective due to workmanship or materials, Resideo shall
repair or replace it (at Resideo's option).
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the place from which
you purchased it; or
(ii) Customer Care will make the determination whether the product should be returned
to the following address: Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley,
MN 55422, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall not
apply if it is shown by Resideo that the defect was caused by damage which occurred
while the product was in the possession of a consumer.
Resideo's sole responsibility shall be to repair or replace the product within the terms
stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY
WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS
PRODUCT.
Some states do not allow the exclusion or limitation of incidental or consequential
damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDEO MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE FIVE YEAR DURATION OF THIS
WARRANTY. Some states do not allow limitations on how long an implied warranty
lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary
from state to state. If you have any questions concerning this warranty, please write
Resideo Customer Care, 1985 Douglas Dr, Golden Valley, MN 55422.
Resideo Technologies, Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
33-00540EFS-01 M.S. Rev. 05-20 | Printed in United States
www.resideo.com
© 2020 Resideo Technologies, Inc. All rights reserved.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.
2 AA size alkaline batteries
2, 3, 4 or 5 wires
1.5 A/30 VAC per output
12 VDC ± 10%, 2.3 mA
4 programs/day, 28 programs total
5 °C to 30 °C (40 °F to 85 °F)
electronic anticipation independent of the load
proportional or conventional
5, 10, 15 or 20 minutes
7.
8.
9.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents