Cables
CAUTION: Electrical installa-
If the cable has too much voltage drop, the
tions must meet local and
inverter may shut down when drawing higher
national wiring codes, and
currents because voltage at the inverter may
should be performed by a
drop below 10 volts. If you must use longer
qualified electrician.
cables choose thicker cables, such as #2 AWG,
and trim the ends of the cable to fit the termi-
CAUTION: Do not connect the
nals.
inverter and another AC source
Strip back the insulation about 1/2 inch (1.25cm),
(such as a generator or utility
on the end of the cable that connects to the
power) to the AC wiring at the
inverter, exposing the bare cooper conductor.
same time. The inverter will be
The other end of the cable that connects to bat-
damaged if its output is con-
tery must be terminated with a battery terminal
nected to AC voltage from
that clamps to the post on the
another source. Damage can
battery.
even occur if the inverter is
switched Off.
CAUTION: Do not connect the
inverter to an AC branch circuit
that has high-power con-
sumption loads. It will not
operate electric heaters, air
conditioners, stoves, and other
electrical appliances that con-
sume more than 2000 watts.
10

Ground Wiring

There is a screw on the rear panel labeled Chassis
Ground. This is to connect the chassis of the
inverter to ground. The ground terminal in the AC
outlet on the right side panel of the inverter is
connected to the chassis.
The Chassis Ground screw must be connected to
a grounding point, which will vary depending on
where the unit is installed. Use a #8 AWG copper
wire (preferably with green/yellow insulation) to
connect the chassis ground screw to the ground-
ing point.
• In a vehicle, connect the Chassis Ground to the
chassis of the vehicle.
• In a boat, connect to the boat grounding
system.
• In a fixed location, connect the Chassis Ground
screw to earth ground by connecting to a
ground rod (a metal rod pounded into the
earth) or other proper service entrance
ground.
Ground Wiring
Ground
Wiring
Warning: Do not operate the
inverter without connecting it
to ground. Electrical shock
hazard may result.