Leviton Decora Illumatech IPX06-1 Installation Instructions page 2

Single pole (one location) or 3-way (multi-location) fluorescent slide dimmer

Advertisement

Single-Pole Wiring Application:
Step 5a
This wire is used in 3-way installations only.
For single pole installations, do not remove this
insulating label.
Red
Black
Neutral
Ground
Green
Red
straight then twist
Dimmer
Red
Hot (Black)
Black
Red
Black
Line
Insulating
Label
120/277VAC, 60Hz
White
Green
Ground
Neutral (White)
Connect wires per WIRING DIAGRAM as follows:
Screw wire nuts on clockwise making sure no bare
conductors show below the wire connectors. Secure each
connector with electrical tape.
NOTE: Dimmer can be installed on either the Load or Line
side.
• Green dimmer Ground lead to Green or bare copper
wire in wall box.
• Black dimmer lead to any wall box wire removed
from old switch.
• Red dimmer lead without insulating label to remaining
wall box wire. Proceed to Step 6.
• Remaining Red dimmer lead should have Red insulation
label affixed. Proceed to Step 6.
NOTE: If insulating label is not affixed to Red lead, use a
small wire nut or electrical tape to cap off. Proceed to Step 6.
3-Way Wiring Application:
Step 5b
Black
Neutral
Red
Ground
Green
straight then twist
Red
Tag
Dimmer
3-Way Switch
(Black Screw)
Hot (Black)
Black
Red
Red
Line
120/277VAC, 60Hz
Green
Green
Ground
Ground
Neutral (White)
Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton's only obligation is to correct such
defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York
11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under
normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied
warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this
warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
Connect wires per WIRING DIAGRAM as follows:
Step 5b
Screw wire nuts on clockwise making sure no bare
con't
conductors show below the wire connectors. Secure each
connector with electrical tape.
NOTE: Dimmer can be installed on either the Load or Line
side.
• Green dimmer Ground lead to Green or bare copper wire
• Black dimmer lead to tagged (common) wall box wire
Electrical
Tape
• Remove Red insulating label from Red lead.
• Any Red dimmer lead to any of the remaining
Insert wires
• Remaining Red dimmer lead to remaining wall box wire.
clockwise
Testing your Dimmer prior to mounting in wall
Step 6
box:
Primary
Side
To Lamps
Red
Blue
Ballast
Yellow
Dimmer Mounting:
Step 7
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Electrical
Tape
Restore Power:
Step 8
fuse. Installation is complete.
Insert wires
clockwise
Common
OPERATION
Terminal
NOTE: If using the dimmer in a 3-way application, the lights will
Primary
Side
To Lamps
turn ON at brightness set on dimmer's slide control lever. The
lighting level can be controlled from either the dimmer or the
Red
Black
switch location.
Blue
Ballast
Yellow
White
in wall box.
identified when removing old switch.
wall box wires.
• Restore power at circuit breaker or
fuse.
• Carefully holding Dimmer as
shown, move slider control lever to
highest position. Lights should turn
ON to brightest level. If lights do not
turn ON, depress push-button switch
once. Lights should turn ON to
brightest level.
If lights still do not turn ON, refer
to the TROUBLESHOOTING
section.
Installation may now be completed
by carefully positioning
all wires to provide room in wall box
for dimmer. Mount dimmer
into box with mounting screws
supplied. Attach wallplate.
Restore power at circuit breaker or
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
ON/OFF:
Depress push-button switch to ON
position - Lights will turn ON.
Depress push-button switch to OFF
position - Lights will turn OFF.
BRIGHTEN & DIM:
Move slider control lever - Lights will
BRIGHTEN or DIM.
TROUBLESHOOTING
For non-standard wiring
applications, refer to Wire
• Lights Flickering
Nut and Connector Size Chart
- Lamp has a bad connection.
WIRE CONNECTOR / # OF COND.
- Wires not secured firmly with
COMBINATION CHART
wire connectors.
• Light does not turn ON and
1- #12 w/ 1 to 3 #14, #16 or #18
ON/OFF LED does not turn ON
2- #12 w/ 1 or 2 #16 or #18
- Circuit breaker or fuse has
1- #14 w/ 1 to 4 #16 or #18
tripped.
2- #14 w/ 1 to 3 #16 or #18
- Lamp is burned out.
- Sockets are not Rapid Start type.
- Lamp Neutral connection is not wired.
NOTE: If further information is needed in identifying the HOT wire
in a 3-Way application, go to Leviton's website at www.leviton.com.
Cat. No. IPXØ6-1, 120V, For use with
Cat. No. IPX1Ø-1, 120V, For use with
Advance Transformer 120V Mark 10™
Advance Transformer 120V Mark 10™
Powerline Electronic Ballasts
Powerline Electronic Ballasts
Max. # Ballasts/
Advance
Advance
Dimmer for Multi-gang
Mark 10™
Mark 10™
Lamp
Powerline
Powerline
Single
Two
More than
Part No.
Part No.
Gang
Ganged
2 Gang
13
REZ-IT32
CFM26W/GX24Q
19
16
REZ-1T32
10
REZ-IT32
CFM32W/GX24Q
16
13
REZ-1T32
8
REZ-IT42
CFM42W/GX24Q
12
10
REZ-1T42
REZ-2Q26
CFQ26W/G24Q
10
9
7
REZ-2Q26
REZ-132
19
16
13
REZ-132
F25T8
10
8
7
REZ-2S32
F25T8
REZ-2S32
5
REZ-3S32
F25T8
7
6
REZ-3S32
11
REZ-132
F32T8
17
14
REZ-132
REZ-2S32
F32T8
8
7
6
REZ-2S32
REZ-3S32
F32T8
6
5
4
REZ-3S32
REZ-1TTS40
15
12
10
REZ-1TTS40
FT40W/2G11
5
REZ-2TTS40
FT40W/2G11
7
6
REZ-2TTS40
Cat. No. IPXØ6-7, 277V, For use with
Cat. No. IPX12-7, 277V, For use with
Advance Transformer 277V Mark 10™
Advance Transformer 277V MarkX™
Powerline Electronic Ballasts
Powerline Electronic Ballasts
Max. # Ballasts/
Advance
Advance
Dimmer for Multi-gang
Mark 10™
Mark 10™
Lamp
Powerline
Single
Two
More than
Powerline
Part No.
Part No.
Gang
Ganged
2 Gang
20
VEZ-1T32
CFM26W/GX24Q
20
20
VEZ-1T32
VEZ-1T32
CFM32W/GX24Q
15
15
15
VEZ-1T32
VEZ-1T42
12
12
12
CFM42W/GX24Q
VEZ-1T42
10
VEZ-2Q26
CFQ26W/G24Q
10
10
VEZ-2Q26
20
VEZ-132
F25T8
20
20
VEZ-132
10
VEZ-2S32
F25T8
10
10
VEZ-2S32
VEZ-3S32
F25T8
7
7
7
VEZ-3S32
VEZ-132
F32T8
17
17
17
VEZ-132
VEZ-2S32
8
8
8
F32T8
VEZ-2S32
6
VEZ-3S32
F32T8
6
6
VEZ-3S32
14
VEZ-1TTS40
FT40W/2G11
14
14
VEZ-1TTS40
7
VEZ-2TTS40
FT40W/2G11
7
7
VEZ-2TTS40
Max. # Ballasts/
Dimmer for Multi-gang
Lamp
Single
Two
More than
Gang
Ganged
2 Gang
CFM26W/GX24Q
32
26
22
CFM32W/GX24Q
26
21
18
CFM42W/GX24Q
20
16
14
CFQ26W/24Q
17
14
12
F25T8
32
26
22
F25T8
17
13
12
F25T8
11
9
8
F32T8
28
22
19
F32T8
14
11
10
F32T8
9
8
7
FT40W/2G11
25
20
17
FT40W/2G11
12
10
9
Max. # Ballasts/
Dimmer for Multi-gang
Lamp
Single
Two
More than
Gang
Ganged
2 Gang
CFM26W/GX24Q
39
39
39
31
31
31
CFM32W/GX24Q
24
CFM42W/GX24Q
24
24
21
CFQ26W/G24Q
21
21
39
F25T8
39
39
F25T8
20
20
20
14
14
14
F25T8
33
33
33
F32T8
17
F32T8
17
17
11
F32T8
11
11
FT40W/2G11
29
29
29
FT40W/2G11
14
14
14
PK-92950-10-00-2D