COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils (Coil Only Ratings)
UNIT MODEL
MODEL
FC/MC/PC18
FC/MC/PC24
YHJD18S41S2
FC/MC/PC30
UC24
UC30
FC/MC/PC32
FC/MC/PC35
YHJD24S41S4
FC/MC/PC37
FC/MC/PC43
FC/MC/PC32
FC/MC/PC35
YHJD30S41S4
FC/MC/PC37
FC/MC/PC43
FC/MC/PC37
FC/MC/PC43
YHJD36S41S4
FC/MC/PC48
UC48
FC/MC/PC60
YHJD42S41S4
UC60
FC/MC/PC60
YHJD48S41S4
FC/MC62
UC60
FC/MC62
YHJD60S41S5
FC64
1. Requires a S1-2FD06700224 Blower Time Delay unless a standard furnace is equipped with one.
MA Modular Air Handlers use Coil Only Ratings.
PSC furnaces, such as the TG8S, TGLS, and TG9S, use Coil Only Ratings.
COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
MODEL
T*(8,L)V*A12
T*(8,L)V*A12
T*(8,L)V*A12
T*(8,L)V*A12
T*(8,L)V*A12
T*(8,L)V*A12
T*(8,L)V*B12
T*(8,L)V*B12
YHJD18S41S2
T*(8,L)V*B12
T*(8,L)V*B12
T*(8,L)V*B12
T*(8,L)V*B12
T*(8,L)X*A12
T*(8,L)X*A12
T*(8,L)X*A12
T*(8,L)X*A12
For Notes See Page 12.
6
COIL
CFM RANGE
(Min.-max.)
WIDTH
13 SEER HP COIL ONLY RATINGS
14.5,17.5
450 - 750
14.5,17.5
450 - 750
14.5,17.5
450 - 750
14.5,17.5
450 - 750
14.5,17.5
450 - 750
14.5
600 - 1000
17.5,21.0
600 - 1000
14.5
600 - 1000
17.5,21.0
600 - 1000
14.5
800 - 1200
17.5,21.0
800 - 1200
14.5
800 - 1200
17.5,21.0
800 - 1200
14.5
1000 - 1400
17.5,21.0
1000 - 1400
21.0,24.5
1000 - 1400
21.0,24.5
1000 - 1400
21.0,24.5
1200 - 1600
21.0,24.5
1200 - 1600
21.0,24.5
1400 - 1800
24.5
1400 - 1800
21.0,24.5
1400 - 1800
24.5
1600 - 2000
24.5
1600 - 2000
FURNACE
COIL
MODEL
WIDTH
13 SEER HP WITH HIGH EFFICIENCY MOTOR FURNACES
14.5
FC/MC/PC18A
14.5
FC/MC/PC24A
14.5
FC/MC/PC30A
14.5
UC18A
14.5
UC24A
14.5
UC30A
14.5
FC/MC/PC18A
17.5
FC/MC/PC24B
17.5
FC/MC/PC30B
17.5
UC18B
17.5
UC24B
17.5
UC30B
14.5
FC/MC/PC18A
14.5
FC/MC/PC24A
14.5
FC/MC/PC30A
14.5
UC18B
COOLING
NET MBH
RATED
CFM
TOTAL
600
18.0
600
18.0
600
18.0
600
18.0
600
18.0
800
23.8
800
23.6
800
24.0
800
24.0
1000
29.8
1000
29.8
1000
30.0
1000
30.0
1200
36.0
1200
36.0
1200
36.0
1200
36.0
1400
41.0
1400
40.5
1600
44.0
1600
44.5
1600
44.0
1800
57.5
1800
56.5
Net MBH
RATED
1
CFM
TOTAL
2
620
18.0
640
18.0
640
18.0
620
18.0
640
18.0
640
18.0
620
18.0
575
18.0
575
18.0
580
18.0
575
18.0
575
18.0
540
18.0
595
18.0
595
18.0
590
18.0
1
SEER
EER
SENS.
14.0
13.00
11.00
14.0
13.50
11.00
13.7
13.00
11.00
13.8
13.05
11.00
13.8
13.05
11.00
17.1
13.00
11.00
17.1
13.00
11.00
17.3
13.00
11.00
17.3
13.00
11.00
21.8
13.00
11.00
21.8
13.00
11.00
22.2
13.00
11.00
22.2
13.00
11.00
26.8
13.00
11.00
26.6
13.00
11.00
26.6
13.00
11.00
26.8
13.00
11.00
31.8
13.00
11.00
31.0
13.00
11.00
33.4
13.00
11.00
33.8
13.00
11.00
32.8
13.00
11.00
41.0
13.25
11.35
42.5
13.00
11.00
COOLING
SEER
EER
SENS.
12.3
14.50
12.30
12.7
14.80
12.50
12.7
14.80
12.50
12.4
14.60
12.30
12.8
14.80
12.50
12.8
14.80
12.50
12.3
14.50
12.30
12.2
14.90
12.60
12.2
14.90
12.60
12.0
14.60
12.30
12.3
14.90
12.60
12.3
15.00
12.60
14.3
14.00
12.00
14.9
14.00
12.00
14.9
14.00
12.00
13.9
14.50
12.00