Download Print this page

York LX Series Technical Manual page 43

Split-system heat pumps
Hide thumbs Also See for LX Series:

Advertisement

HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
EVAPORATOR COIL MODEL NO
AIR TEMP.
AIR TEMP.
ENTERING
ENTERING
OUTDOOR UNIT
INDOOR COIL
60
47
40
30
17
10
NOTE: ALL CAPACITIES ARE NET, WITH INDOOR FAN HEAT ALREADY DEDUCTED. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Multipliers for determining the performance with other indoor sections.
Air Handlers
Coils
FC/MC/PC60
FC/MC62
UC60
AHE48D
AHE60D
AHR48D
AHR60D
AHV48D
AHV60D
AV*48
AV*60
MV16C
FC60C
MV20D
FC/MC60D
MV20D
FC/MC62D
MX16C
FC60C
MX20D
FC/MC60D
MX20D
FC/MC62D
Furnaces
Coils
T*(8,L)V*C16
FC/MC62D
T*(8,L)V*C16
FC/PC60C
T*(8,L)V*C16
UC60C
T*(8,L)V*C20
FC/MC62D
T*(8,L)V*C20
FC/PC60C
T*(8,L)V*C20
UC60C
T*(8,L)X*C16
FC/MC62D
T*(8,L)X*C16
FC/PC60C
T*(8,L)X*C16
UC60C
T*(8,L)X*C20
FC/MC62D
T*(8,L)X*C20
FC/PC60C
T*(8,L)X*C20
UC60C
T*9(C,V)*C16
FC/MC62D
Johnson Controls Unitary Products
YHJD48S41S4
AHP48
1400
MBH
COP
60
53.4
3.7
70
51.9
3.5
80
50.4
3.3
60
46.3
3.6
70
46.5
3.7
80
46.7
3.7
60
42.6
3.5
70
39.8
3.3
80
37.0
3.0
60
32.1
3.1
70
31.7
2.9
80
31.4
2.8
60
27.2
2.8
70
26.6
2.7
80
24.2
2.4
60
23.1
2.6
70
21.7
2.3
80
20.3
2.1
MBH
COP
KW
1.00
1.00
1.00
0.99
1.01
0.98
1.00
1.02
0.98
0.98
1.06
0.92
0.97
1.06
0.91
0.97
0.98
0.98
0.99
1.01
0.98
0.97
1.02
0.95
0.98
1.03
0.95
0.98
1.07
0.92
0.98
1.07
0.91
0.98
1.06
0.93
0.98
1.06
0.93
0.98
1.06
0.93
0.98
1.09
0.90
0.97
1.09
0.89
0.98
1.08
0.91
MBH
COP
KW
0.99
1.03
0.96
0.99
1.03
0.96
0.99
1.03
0.96
0.99
1.04
0.95
0.99
1.04
0.95
0.99
1.05
0.95
0.98
1.05
0.94
0.98
1.06
0.93
0.99
1.05
0.95
0.98
1.05
0.93
0.98
1.06
0.92
0.97
1.09
0.89
0.99
1.03
0.96
ID CFM
1600
KW
MBH
COP
4.17
53.2
3.7
4.32
52.0
3.5
4.45
50.8
3.3
3.75
46.6
3.6
3.71
46.0
3.5
3.68
45.4
3.5
3.52
42.8
3.5
3.57
40.3
3.3
3.63
37.8
3.0
3.04
33.2
3.1
3.16
32.7
3.0
3.29
32.2
2.8
2.82
28.1
2.9
2.89
27.6
2.7
2.96
25.1
2.4
2.62
24.4
2.6
2.71
22.7
2.4
2.80
21.1
2.1
Furnaces
Coils
T*9(C,V)*C16
FC/PC60C
T*9(C,V)*C16
UC60C
T*9(C,V)*C20
FC/MC62D
T*9(C,V)*C20
FC/PC60C
T*9(C,V)*C20
UC60C
T*9(C,V)*D20
FC/MC/PC60D
T*9(C,V)*D20
FC/MC62D
T*9(C,V)*D20
UC60D
T*9X*C16
FC/MC62D
T*9X*C16
FC/PC60C
T*9X*C16
UC60C
T*9X*C20
FC/MC62D
T*9X*C20
FC/PC60C
T*9X*C20
UC60C
T*9X*D20
FC/MC/PC60D
T*9X*D20
FC/MC62D
T*9X*D20
UC60D
Y*(8,L)C*C16
FC/MC62D
Y*(8,L)C*C16
FC/PC60C
Y*(8,L)C*C16
UC60C
Y*(8,L)C*C20
FC/MC62D
Y*(8,L)C*C20
FC/PC60C
Y*(8,L)C*C20
UC60C
Y*9C*C16
FC/MC62D
Y*9C*C16
FC/PC60C
Y*9C*C16
UC60C
Y*9C*C20
FC/MC62D
Y*9C*C20
FC/PC60C
Y*9C*C20
UC60C
Y*9C*D20
FC/MC/PC60D
Y*9C*D20
FC/MC62D
Y*9C*D20
UC60D
571209-YTG-C-1012
1800
KW
MBH
COP
4.17
53.1
3.7
4.31
52.2
3.6
4.46
51.3
3.4
3.77
46.9
3.6
3.85
45.5
3.4
3.84
44.2
3.2
3.55
43.0
3.5
3.61
40.8
3.3
3.68
38.7
3.0
3.12
34.4
3.1
3.24
33.7
3.0
3.36
32.9
2.8
2.88
29.0
2.9
2.98
28.5
2.7
3.05
26.1
2.4
2.72
25.7
2.7
2.81
23.7
2.4
2.90
21.8
2.1
MBH
COP
0.99
1.03
0.99
1.02
0.99
1.02
0.99
1.03
0.99
1.02
0.99
1.04
0.99
1.02
0.99
1.03
0.99
1.04
0.98
1.05
0.99
1.05
0.98
1.05
0.98
1.06
0.98
1.06
0.97
1.09
0.99
1.04
0.97
1.07
0.99
1.03
0.99
1.03
0.99
1.03
0.99
1.04
0.99
1.04
0.99
1.05
0.99
1.03
0.99
1.03
0.99
1.02
0.99
1.02
0.99
1.03
0.99
1.02
0.99
1.04
0.99
1.02
0.99
1.03
KW
4.16
4.30
4.46
3.78
3.97
4.01
3.58
3.65
3.72
3.21
3.31
3.42
2.95
3.07
3.14
2.83
2.91
2.99
KW
0.96
0.97
0.97
0.96
0.97
0.95
0.97
0.96
0.95
0.93
0.95
0.93
0.92
0.93
0.89
0.95
0.90
0.96
0.96
0.96
0.95
0.95
0.95
0.96
0.96
0.97
0.97
0.96
0.97
0.95
0.97
0.96
43

Advertisement

loading