Operation And Adjustment; Operation Panel - Toshiba TOSVERT VF-A5 Instruction Manual

High-performance inverter
Hide thumbs Also See for TOSVERT VF-A5:
Table of Contents

Advertisement

E6580516
7. Operation and Adjustment
7.1 Operation Panel
The operation panel (hereafter, panel) allows the inverter to
be
operated. and functions and data to
be
set
and monitored.
Panel control LED
This LED will light when
"Panel control" is selected.
The inverter can be operated
from the panel when this
LED is lit, and it will blink
while running.
Panel/remote key
Changes between "Panel
operation" and
"Terminal
block operation".
UP key (.6) and DOWN key
('V)
LED display
The LED display normally indicates the operating frequency.
During status monitoring, various conditions can be monitored, and the
frequency command value can be
displayed.
During parameter settings, the groups or parameter titles and setting
values can be displayed. During a fault, the cause will be displayed.
<D
Lights during operating frequency setting, status monitor mode
displaying, and displaying of a group name, parameter name or
parameter setting value.
cg)
Refer to Appendix 3, Character codes (page 131 ).
@
Lights during option priority operation
(Refer to the Instruction Manual for the oprion for details.)
®
Units LEDs
l~l
When a numerical value is
displayed, it can be
incremented/decremented
\ -,_ -----------_ -_ -----_:-_ ----- . .....
-""°'
with these keys. When a
\
~
When a numerical value is
displayed on the LED display, the
LED corresponding to the
numerical value's units will light.
(No LEDs will be lit when A or V
units are selected.)
.,-,,-,,-,,-,
.I
~~~~-----------~
symbol is displayed, the next
,-,
1 - 11 -; ;-; __..-r:;;.. .- ,,
\
·- -
-~__...........,_,,,,.
ipt~emss~~gn
tbheedseestetaysyed by
\
z
EC
a-%
Run key
~, ,
1
....
Monitor key
Changes between status monitor
- - mode and frequency display
status.
I-
_ _ _ _ _ _ _ · _ _ _ _ , ,
~~ePAN8BELCONTROL
Initiates running. This key is
""'~E
r---
Program key
valid only when "Panel
1 - - - - - - - - - - - - - - 1
control" is selected.
r--.......
6,
V
ENTER]
Changes between settings
'----------------J· -......_
~
monitor mode and frequency
Stop/reset key
.... " '
J
1
STOP
I'-
display
status.
RUN
I RESET
~:===================~
-----/1-----"~
Enter key
1 - - - - - - - - - - - - - - 1
Selects or sets the parameter
name, data or frequency, etc.
This key functions as the stop key during
"Panel
control". In all other
modes, emergency stop is engaged when this key is pressed twice.
During an inverter trip, the tripped state can be reset by pressing this
key twice.
(Refer to section 7.4.7 Fault reset.)