2) Set the copy magnification ratio to 100%.
3) Make a copy on A4 or 81/2" x 11" paper.
4) Measure the length of the copied scale image.
5) Calculate the main scanning direction magnification ratio.
Main scanning direction magnification ratio
Copy image dimensions
=
Original dimension
(When a 100mm scale is used as the original.)
mm
10
20
1/2mm
Paper feed
mm
10
20
direction
1/2mm
Reference
6) Check that the copy magnification ratio is within the specified range.
If it is not within the specified range, perform the following
procedures.
7) Execute SIM 48-1 to select the main scanning direction copy
magnification ratio adjustment mode.
To select the adjustment mode, use the copy mode select key.
In the case of the automatic adjustment, when the PRINT switch is
pressed, the mirror base unit moves to the white plate for shading to
scan the width of the reference line, calculating the correction value and
displaying and storing this value.
After execution of the automatic adjustment, go out from the simulation
mode and make a copy to check the magnification ratio.
If the magnification ratio is not in the specified range (100±1.0%),
manually adjust as follows.
Adjustment mode
Main scanning direction auto copy
magnification ratio adjustment
Main scanning direction manual copy
magnification ratio adjustment
Sub scanning direction copy
magnification ratio adjustment
8) Set the adjustment mode to Manual with the copy mode select key.
9) Enter the new set value of main scanning direction copy
magnification ratio with the copy quantity set key, and press the
COPY button.
10) Change the set value and repeat the adjustment until the ratio is
within the speoified range.
When the set value is changed by 1, the magnification ratio is
changed by 0.1%.
(3) Sub scanning direction copy magnification ratio
a. Note
Before performing this adjustment, the following adjustments must have
been completed. If not, this adjustment cannot be performed properly.
• Image distortion adjustment
• Must be installed to the lens unit reference position.
X 100 (%)
Original (Scale)
HARDDENCD
STAINLESS
JAPAN
150
100
110
120
130
140
Shizuoka
HARDDENCD
STAINLESS
JAPAN
150
100
110
120
130
140
Shizuoka
Comparison point
Copy
110
Lighting lamp
Auto exposure lamp ON
Manual exposure lamp ON
Photo exposure lamp ON
AL-1551 ADJUSTMENTS 9-5
b. Cases when the adjustment is required
1) When the lens and the mirror unit are disassembled or the part is
replaced.
2) When the scanner unit drive section is disassembled or the part is
replaced.
3) When the main PWB is replaced.
4) When the EEPROM in the main PWB is replaced.
5) When "U2" trouble occurs.
6) When the copy image distortion adjustment is performed.
c. Necessary tools
• Screwdriver (+)
• Scale
d. Adjustment procedure
1) Set the scale on the document table as shown below. (Use a long
scale for precise adjustment.)
2) Set the copy magnification ratio to 100%.
3) Make a copy on A4 or 81/2" x 11" paper.
4) Measure the length of the copied scale image.
5) Calculate the sub scanning direction copy magnification ratio.
Sub scanning direction copy magnification ratio
Copy image dimensions
=
Original dimension
mm
10
20
100
110
1/2mm
mm
10
20
100
110
1/2mm
Reference
Comparison point
X 100 (%)
110
Original (Scale)
HARDDENCD
STAINLESS
JAPAN
150
120
130
140
Shizuoka
Paper feed
HARDDENCD
STAINLESS
direction
JAPAN
150
120
130
140
Shizuoka
Copy

Advertisement

loading

This manual is also suitable for:

Al-1252Al-1452Al-1551