Page 2
AIR CARE SEMINAR TRAINING Sullair Air Care Seminars are courses that provide hands-on instruction for the proper operation, maintenance, and servicing of Sullair products. Individual seminars on Stationary compressors and compressor electrical systems are offered at regular intervals throughout the year at Sullair’s corporate headquarters training facility located at Michigan City, Indiana.
TABLE OF CONTENTS SECTION 1—SAFETY SAFETY INFORMATION SECTION 2—RD SERIES DRYER INTRODUCTION SPECIFICATIONS SAFETY INSTRUCTIONS ISSUES TO AVOID RECEIVING AND INSPECTION TRANSPORTATION INSTALLATION LAYOUT REQUIREMENTS ENVIRONMENTAL PROTECTION PRODUCT DESCRIPTION 2.10 PRODUCT FEATURES 2.11 PRINCIPLE OF OPERATION 2.12 COMPRESSED AIR HEAT EXCHANGER 2.13 PIPE/CONNECTION REQUIREMENTS 2.14...
Page 4
TABLE OF CONTENTS ED/SPARE PARTS—RD500 AIR COOLED ED/SPARE PARTS—RD700 AIR COOLED ED/SPARE PARTS—RD700 WATER COOLED ED/SPARE PARTS—RD850 AIR COOLED ED/SPARE PARTS—RD850 WATER COOLED ED/SPARE PARTS—RD1000 AIR COOLED ED/SPARE PARTS—RD1000 WATER COOLED ED/SPARE PARTS—RD1200 AIR COOLED 4.10 ED/SPARE PARTS—RD1200 WATER COOLED 4.11 ED/SPARE PARTS—RD1600 AIR COOLED 4.12...
Page 5
TABLE OF CONTENTS 4.44 WIRING DIAGRAM—RD (700-850-1000-1200-1600-2000-2400-3000- 3800-5000-6000) 460-3-60-W, 400-3-50-W 4.45 CONTROL CIRCUIT—RD400-500-700-850-1000-1200-1600-2000-2400- 3000-3800-5000-6000 4.46 POWER CIRCUIT—RD400-500-700-850-1000-1200-1600-2000-2400- 3000-3800-5000-6000...
The equipment design, development, production, compressed air service. Also all “end user” safety assembly and customer service fall under the Sullair rules for the same type of service must be adhered quality control system.
If your application does not match the above criteria, heats up the exiting air, thereby eliminating the contact your Sullair distributor and they will be able to chances of freezing even in relatively cooler ambient provide the right dryer for your application.
INSPECTION observe all local safety instructions and rele- vant regulations. Sullair dryers are factory tested prior to shipment. 2. Prior to installation, the dryer and the com- However, during shipment, there are chances that pressed air system are to be depressurized...
SECTION 2 PRODUCT USER MANUAL INSTALLATION LAYOUT The minimum and maximum values stated must be REQUIREMENTS observed, as well as the safety precautions described in this manual. 1. The dryer must be installed horizontally. A minimum of at least 1.5 feet / 0.5 meters clearance around the dryer is necessary to 2.10 PRODUCT FEATURES allow free air circulation and easy access for...
• Total working hours Membrane disc may need to be replaced time to time • Total economy hours due to contamination in the air circuit. Contact Sullair • Real date and time or its distributer if there is any drain blockage issues.
SECTION 2 PRODUCT USER MANUAL 3. Control circuit including: Compressor, meter- gaseous refrigerant into the low pressure refrigerant ing device, hot gas by-pass valve (if circuit. installed), fan pressure switch, safety high/ 2.12 COMPRESSED AIR HEAT low pressure switch. Water cooled dryers are EXCHANGER equipped with...
PRODUCT USER MANUAL SECTION 2 2.13 PIPE/CONNECTION 2.14 ELECTRICAL CONNECTION REQUIREMENTS REQUIREMENTS Refer to Product Models and Specifications— The owner shall furnish all labor, materials, Table 2-2, Table 2-3, Table 2-4, Table 2-5. equipment services necessary reasonably incidental to complete the installation of all electrical as shown on the drawings.
Page 15
If you are in doubt, contact your Sullair distrib- 4. In Line Filters: install one compressed air fil- utor. It is recommended to use the same pipe ter in line (particulate filter) before the dryer size as that of the dryer Inlet and Outlet.
PRODUCT USER MANUAL SECTION 2 2.17 STEPS TO UNDERTAKE 6. Remove any packaging and other material BEFORE OPERATING which could obstruct the area around the dryer. 1. Read this manual completely. 7. Activate the mains switch. 2. Review all safety precautions. 8.
SECTION 2 PRODUCT USER MANUAL 2.19 STARTUP AND SHUT DOWN SEC 3.24 S HUT DOWN PROCEDURE 1. Shut down the air compressor. 2. After few minutes, shut down the dryer pressing the button "0 - OFF" of the digital WARNING controller For short periods of inactivity, (max 2-3 NOTE...
PRODUCT USER MANUAL SECTION 2 2.20 MAINTENANCE 2.20.2 M AINTENANCE BY THE USER 1. Keep the dryer clean. 2.20.1 M AINTENANCE BY AN NGINEER 2. In case of more than 4 pounds of refrigerant, ECHNICIAN the dryer should be regularly checked to be 1.
SECTION 2 PRODUCT USER MANUAL 2.21 TROUBLESHOOTING Problem Possible Cause Repair Comments Dryer is switched on, The connection has Invert two phases 3-phase dryers are equipped with indicator light is lit but the inverted phases a phase controller to avoid the refrigerant compressor fans from turning in the opposite does not turn on.
Page 20
PRODUCT USER MANUAL SECTION 2 Problem Possible Cause Repair Comments Dryer is switched on but Clogged condenser fins Clear fins or water The clogged fins in the con- the refrigerant compres- or clogged water condenser of all denser will restrict the air pas- sor does not turn on.
Page 21
SECTION 2 PRODUCT USER MANUAL Problem Possible Cause Repair Comments Water in system Compressed Air Inlet and Check inlet and outlet connec- This dryer is designed for air flow outlet connections are tions. in one direction only. Inlet and reversed. outlet directions are identified on the dryer.
Page 22
PRODUCT USER MANUAL SECTION 2 Problem Possible Cause Repair Comments Water in system Excessive free moisture Check the separator In some system there may be an and drain system and com- accumulation of free moisture in pressor after cooler the line ahead of the dryer. If this ahead of the dryer.
Page 23
Some contamination may require extra maintenance of the heat exchanger. Contact your Sullair Distributor. The unit will not run or Line disconnect switch is Close the start or disconnect If the dryer is not operating, cycles off and on.
Page 24
PRODUCT USER MANUAL SECTION 2 Problem Possible Cause Repair Comments The unit will not run or Excessive compressed air Design conditions and correc- The dryer is designed for working cycles off and on. inlet temperature. tion factors are described in into calculated design conditions.
Drain On Time (Second) Timer drain is "on" during that time Filter Change Period (Hour) Warning to the customer to replace the elements of their filters 8000 General Maintenance Period (Hour) Warning to the customer to get a service from Sullair 20000...
Page 26
Table 2-2: DP Power 60H Rated STANDARD Capacity SCFM @ AIR COOLED MODEL WATER COOLED Pressure Absorbed GROUP SULLAIR PART SULLAIR PART Flow Port Size VOLTAGE Rated Conditions MODEL REF Drop Power scfm (psid) (kW) (in) Non- 230/3/60 RD-0400-230-60-A 02250193-849 1.92...
Page 27
Table 2-2: DP Power 60H Rated STANDARD Capacity SCFM @ AIR COOLED MODEL WATER COOLED Pressure Absorbed GROUP SULLAIR PART SULLAIR PART Flow Port Size VOLTAGE Rated Conditions MODEL REF Drop Power scfm (psid) (kW) (in) Non- 575/3/60 2500 RD-2400-575-60-A...
Page 28
Table 2-3: DP Power 50H Rated STANDARD Capacity SCFM @ AIR COOLED MODEL WATER COOLED Pressure Absorbe GROUP SULLAIR PART SULLAIR PART Flow Port Size VOLTAGE Rated Conditions MODEL REF Drop d Power scfm (psid) (kW) (in) Non-Cycling 400/3/50 3000...
Page 29
Table 2-4: Models 60HZ Capacity WATER Rated STANDARD SCFM @ AIR COOLED SULLAIR SULLAIR Pressure Absorbed GROUP COOLED Flow Port Size Width Height Depth Weight VOLTAGE Rated MODEL REF PART PART Drop Power MODEL REF Conditions scfm (psid) (kW) (in)
Page 30
Table 2-5: Models 50Hz Capacity SCFM Rated STANDARD AIR COOLED MODEL SULLAIR WATER COOLED SULLAIR Pressure Absorbed Port GROUP @ Rated Flow Width Height Depth Weight VOLTAGE PART MODEL REF PART Drop Power Size Conditions scfm (psid) (kW) (in) mm lbs 4"FLG 45.9 1166 79.9 2030 61.0 1550 1705 775...
CONTROLLER FOR REFRIGERANT DRYERS Section 3 CONTROLLER E-680 is designed as a controller for refrigerant type The front panel of the controller contains a four line compressed air dryers. The controller has 8 20 character LCD display and 10 buttons that are temperature sensor inputs.
Page 32
CONTROLLER FOR REFRIGERANT DRYERS SECTION 3 The dryer is automatically stopped if an anomaly is buttons are used for starting and stopping detected. In that case, the alarm output and the alarm the dryer respectively. If the dryer is stopped indicator LED on the front panel become activated.
Page 33
D. INPUT 3 Compressor Fault D. INPUT 4 Compressor Overload D. INPUT 5 Fan Fault SULLAIR D. INPUT 6 Fan Overload D. INPUT 7 Phase Sequence Error D. INPUT 8 Remote Disable DEW POINT 16°C...
Page 34
CONTROLLER FOR REFRIGERANT DRYERS SECTION 3 ..INLET AIR TEMP. TOTAL TIME : 22.2 20°C ECO TIME EXCHANGER.TEMP. RUN TIME 22.2 18°C HIGH FILTER TIME: 22.2 LOW PRES.LINE TEMP. 1. REMOTE DISABLE 18°C 2. INLET AIR TEMP.HI HIGH PRES.LINE TEMP. 3.
Page 35
‘SENSOR BREAK’ message is displayed. The fourth screen displays the states of the compressor motor, fan motor, the phase sequence SULLAIR and remote disable. This information is compiled ECO(SEC.) from the digital inputs. (Digital Inputs 3 to 8) DEW POINT 8°C...
Page 36
CONTROLLER FOR REFRIGERANT DRYERS SECTION 3 3.1.3 4. Exchanger Temp. / High Alarm Setpoint ONFIGURATION (68°F/20°C) In order to enter into configuration mode, button 5. Low Pressure Line Temp. / Low Alarm Setpoint must be pressed at least 3 second duration. After this (23°F/-5°C) operation security code is asked.
ED/SPARE PARTS—RD400 AIR COOLED 02250196-586 R03...
Page 41
ED/SPARE PARTS—RD400 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-NUT-1200 CAGE NUT AND SCREW M-CON-0400 CONDENSOR M-SCR-6000 SCREW TYPE 2 SEE REF. TABLE FAN MOTOR ASSEMBLY M-TRF-6000 TRANSFORMER M-DRI-1200 DRYER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-0850 HEAT EXCHANGER M-CNT-0400-400-3-50 CONTACTOR...
Page 42
ED/SPARE PARTS—RD500 AIR COOLED 02250196-588 R03...
Page 43
ED/SPARE PARTS—RD500 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-0500 CONDENSOR M-TRF-6000 TRANSFORMER SEE REF. TABLE FAN MOTOR ASSEMBLY M-PPR-6000 PHASE PROTECTION RELAY M-DRI-1200 DRIER-DEHYDRATOR SEE REF. TABLE CONTACTOR M-EXC-0850 HEAT EXCHANGER M-FCN-1200 FAN CONTACTOR M-EXV-0500...
Page 44
ED/SPARE PARTS—RD700 AIR COOLED 02250196-590 R3...
Page 45
ED/SPARE PARTS—RD700 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-0700 CONDENSOR M-TRF-6000 TRANSFORMER SEE REF. TABLE FAN MOTOR ASSEMBLY M-PPR-6000 PHASE PROTECTION RELAY M-DRI-1200 DRIER-DEHYDRATOR SEE REF. TABLE CONTACTOR M-EXC-0850 HEAT EXCHANGER M-FCN-1200 FAN CONTACTOR M-EXV-0700...
Page 46
ED/SPARE PARTS—RD700 WATER COOLED 02250196-618 R03...
Page 47
ED/SPARE PARTS—RD700 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-0700-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-1200 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-0850 HEAT EXCHANGER SEE REF. TABLE CONTACTOR M-EXV-0850 EXPANSION VALVE COMPRESSOR OVERLOAD SEE REF.
Page 48
ED/SPARE PARTS—RD850 AIR COOLED 02250196-591 R03...
Page 49
ED/SPARE PARTS—RD850 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-0850 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-6000 CAGE NUT AND SCREW M-DRI-1200 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-0850 HEAT EXCHANGER M-TRF-6000...
Page 50
ED/SPARE PARTS—RD850 WATER COOLED 02250196-619 R03...
Page 51
ED/SPARE PARTS—RD850 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-1000-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-1200 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-0850 HEAT EXCHANGER M-CNT-0850 CONTACTOR M-EXV-1000 EXPANSION VALVE COMPRESSOR OVERLOAD SEE REF. TABLE PROTECTOR M-BYV-1200 BY PASS VALVE...
Page 52
ED/SPARE PARTS—RD1000 AIR COOLED 02250196-592 R03...
Page 53
ED/SPARE PARTS—RD1000 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-1000 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-1200 CAGE NUT AND SCREW M-DRI-1200 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000...
Page 54
ED/SPARE PARTS—RD1000 WATER COOLED 02250196-620 R03...
Page 55
ED/SPARE PARTS—RD1000 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-1000-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-1200 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-6000 HEAT EXCHANGER M-CNT-1200 CONTACTOR M-EXV-1000 EXPANSION VALVE COMPRESSOR OVERLOAD M-COP-1200 PROTECTOR M-BYV-1200 BY PASS VALVE M-WVF-1200...
Page 56
ED/SPARE PARTS—RD1200 AIR COOLED 02250196-593 R03...
Page 57
ED/SPARE PARTS—RD1200 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-1200 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-1200 CAGE NUT AND SCREW M-DRI-1200 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000...
Page 58
4.10 ED/SPARE PARTS—RD1200 WATER COOLED 02250196-621 R03...
Page 59
4.10 ED/SPARE PARTS—RD1200 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-1200-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-1200 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-6000 HEAT EXCHANGER M-CNT-1200 CONTACTOR M-EXV-1200 EXPANSION VALVE COMPRESSOR OVERLOAD M-COP-1200 PROTECTOR M-BYV-1200 BY PASS VALVE...
Page 60
4.11 ED/SPARE PARTS—RD1600 AIR COOLED 02250196-594 R03...
Page 61
4.11 ED/SPARE PARTS—RD1600 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-1600 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-6000 CAGE NUT AND SCREW M-DRI-2400 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000...
Page 62
4.12 ED/SPARE PARTS—RD1600 WATER COOLED 02250196-622 R03...
Page 63
4.12 ED/SPARE PARTS—RD1600 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-1600-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-2400 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-6000 HEAT EXCHANGER M-CNT-1600 CONTACTOR M-EXV-1600 EXPANSION VALVE COMPRESSOR OVERLOAD M-COP-1600 PROTECTOR M-BYV-6000 BY PASS VALVE...
Page 64
4.13 ED/SPARE PARTS—RD2000 AIR COOLED 02250196-595 R03...
Page 65
4.13 ED/SPARE PARTS—RD2000 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-2400 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-6000 CAGE NUT AND SCREW M-DRI-2400 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000...
Page 66
4.14 ED/SPARE PARTS—RD2000 WATER COOLED 02250196-623 R03...
Page 67
4.14 ED/SPARE PARTS—RD2000 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-FAS-6000 CABINET FASTENER M-CON-2000-W CONDENSOR M-NUT-6000 CAGE NUT AND SCREW M-DRI-2400 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000 TRANSFORMER M-EXV-2400 EXPANSION VALVE M-PPR-6000 PHASE PROTECTION RELAY M-BYV-6000 BY PASS VALVE...
Page 68
4.15 ED/SPARE PARTS—RD2400 AIR COOLED 02250196-596 R03...
Page 69
4.15 ED/SPARE PARTS—RD2400 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-2400 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-6000 CAGE NUT AND SCREW M-DRI-2400 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000...
Page 70
4.16 ED/SPARE PARTS—RD2400 WATER COOLED 02250196-624 R03...
Page 71
4.16 ED/SPARE PARTS—RD2400 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-2400-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-2400 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-6000 HEAT EXCHANGER M-CNT-2400 CONTACTOR M-EXV-2400 EXPANSION VALVE COMPRESSOR OVERLOAD M-COP-2400 PROTECTOR M-BYV-6000 BY PASS VALVE...
Page 72
4.17 ED/SPARE PARTS—RD3000 AIR COOLED 02250196-597 R03...
Page 73
4.17 ED/SPARE PARTS—RD3000 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-STU-6000 CABINET STUD AND NUT M-CON-3000 CONDENSOR M-FAS-6000 CABINET FASTENER SEE REF. TABLE FAN MOTOR ASSEMBLY M-NUT-6000 CAGE NUT AND SCREW M-DRI-5000 DRIER-DEHYDRATOR M-SCR-6000 SCREW TYPE 2 M-EXC-6000 HEAT EXCHANGER M-TRF-6000...
Page 74
4.18 ED/SPARE PARTS—RD3000 WATER COOLED 02250196-625 R03...
Page 75
4.18 ED/SPARE PARTS—RD3000 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-3000-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-5000 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-6000 HEAT EXCHANGER M-CNT-3000 CONTACTOR M-EXV-3000 EXPANSION VALVE COMPRESSOR OVERLOAD M-COP-3000 PROTECTOR M-BYV-6000 BY PASS VALVE...
Page 76
4.19 ED/SPARE PARTS—RD3800 AIR COOLED 02250196-598 R03...
Page 77
4.19 ED/SPARE PARTS—RD3800 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-CPS-6000 CABINET HANDLE M-CON-3800 CONDENSOR M-STU-6000 CABINET STUD AND NUT SEE REF. TABLE FAN MOTOR ASSEMBLY M-FAS-6000 CABINET FASTENER M-DRI-5000 DRIER-DEHYDRATOR M-NUT-6000 CAGE NUT AND SCREW M-EXC-6000 HEAT EXCHANGER M-SCR-6000...
Page 78
4.20 ED/SPARE PARTS—RD3800 WATER COOLED 02250196-626 R03...
Page 79
4.20 ED/SPARE PARTS—RD3800 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-SCR-6000 SCREW TYPE 2 M-CON-3800-W CONDENSOR M-TRF-6000 TRANSFORMER M-DRI-5000 DRIER-DEHYDRATOR M-PPR-6000 PHASE PROTECTION RELAY M-EXC-6000 HEAT EXCHANGER M-CNT-5000 CONTACTOR M-EXV-3800 EXPANSION VALVE COMPRESSOR OVERLOAD M-COP-3800 PROTECTOR M-BYV-6000 BY PASS VALVE...
Page 80
4.21 ED/SPARE PARTS—RD5000 AIR COOLED 02250196-599 R03...
Page 81
4.21 ED/SPARE PARTS—RD5000 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-CPS-6000 CABINET HANDLE M-CON-6000 CONDENSOR M-STU-6000 CABINET STUD AND NUT SEE REF. TABLE FAN MOTOR M-FAS-6000 CABINET FASTENER M-DRI-5000 DRIER-DEHYDRATOR M-NUT-6000 CAGE NUT AND SCREW M-EXC-6000 HEAT EXCHANGER M-SCR-6000...
Page 82
4.22 ED/SPARE PARTS—RD5000 WATER COOLED 02250196-627 R03...
Page 83
4.22 ED/SPARE PARTS—RD5000 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-CPS-6000 CABINET HANDLE M-CON-5000-W CONDENSOR M-STU-6000 CABINET STUD AND NUT M-DRI-5000 DRIER-DEHYDRATOR M-FAS-6000 CABINET FASTENER M-EXC-6000 HEAT EXCHANGER M-NUT-6000 CAGE NUT AND SCREW M-EXV-5000 EXPANSION VALVE M-SCR-6000 SCREW TYPE 2 M-BYV-6000...
Page 84
4.23 ED/SPARE PARTS—RD6000 AIR COOLED 02250196-600 R03...
Page 85
4.23 ED/SPARE PARTS—RD6000 AIR COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-CPS-6000 CABINET HANDLE M-CON-6000 CONDENSER M-STU-6000 CABINET STUD AND NUT SEE REF. TABLE FAN MOTOR M-FAS-6000 CABINET FASTENER M-DRI-6000 DRIER-DEHYDRATOR M-NUT-6000 CAGE NUT AND SCREW M-EXC-6000 HEAT EXCHANGER M-SCR-6000...
Page 86
4.24 ED/SPARE PARTS—RD6000 WATER COOLED 02250196-628 R03...
Page 87
4.24 ED/SPARE PARTS—RD6000 WATER COOLED PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION SEE REF. TABLE COMPRESSOR M-NUT-6000 CAGE NUTS M-CON-6000-W CONDENSOR M-SCR-6000 SCREWS M-DRI-6000 DRIER-DEHYDRATOR SEE REF. TABLE TRANSFORMER M-EXC-6000 HEAT EXCHANGER M-PPR-6000 PHASE PROTECTION RELAY M-EXV-6000 EXPANSION VALVE M-CNT-6000 CONTACTOR M-BYV-6000 BY PASS VALVE COMPRESSOR OVERLOAD...
Page 103
4.32 ID—RD5000 A (WATER DRYER PART POWER DECAL (1) COOLING CONNECTION NUMBER RATINGS 02250193-928 400V/3Ph/50Hz RD5000 02250193-993 460V/3Ph/60Hz AIR COOLED 02250194-147 575V/3Ph/60Hz DRYER GROSS WEIGHT NET WEIGHT WITHOUT PALLET SIZE WITH PALLET SIZE 59.05” x 115.55” x 78.54” 66.93” x 123.42” x 82.67” RD 5000 2820 LB/1279 kg 2420 LB/1098 kg...
Page 107
4.34 P&I—RD400 POS. DESCRIPTION COMPRESSOR REFRIGERANT CONDENSER FAN MOTOR FAN MOTOR SWITCH EVAPORATOR AIR-AIR EXCHANGER PRESSURE REGULATOR DEHYDRATOR DEW POINT INDICATOR BY-PASS VALVE LIQUID RECEIVER NOTE: MARK/TAG COMPONENT/CONTAINER WITH SULLAIR P/N AND REVISION MODEL REFRIGERANT TYPE RD400 6.613 R134A...
Page 109
REFRIGERANT CONDENSER FAN MOTOR FAN MOTOR SWITCH EVAPORATOR AIR-AIR EXCHANGER PRESSURE REGULATOR DEHYDRATOR DEW POINT INDICATOR BY-PASS VALVE LIQUID RECEIVER LIQUID SEPARATOR NOTE: MARK/TAG COMPONENT/CONTAINER WITH SULLAIR P/N AND REVISION MODEL REFRIGERANT TYPE RD500 8.818 RD700 R134A 9.369 RD850 11.023...
Page 110
4.36 P&I—RD700-850 WATER COOLED 02250195-294...
Page 111
4.36 P&I—RD700-850 WATER COOLED POS. DESCRIPTION COMPRESSOR WATER CONDENSER EVAPORATOR AIR-AIR EXCHANGER PRESSURE REGULATOR DEHYDRATOR DEW POINT INDICATOR BY-PASS VALVE LIQUID RECEIVER LIQUID SEPARATOR NOTE: MARK/TAG COMPONENT/CONTAINER WITH SULLAIR P/N AND REVISION. MODEL REFRIGERANT TYPE RD700 9.369 R134A RD850 11.023...
Page 139
4.44 WIRING DIAGRAM— RD (700-850-1000-1200-1600-2000-2400-3000-3800-5000-6000) 460-3-60-W, 400-3-50-W COMP DESCRIPTION F1,F2 A01 Primary protection F10, F11 Control circuit protection Control circuit transformer Remote control start button Remote control stop button Thermal protection off-on compressor Compressor heat thermal EMR4 Phase protection relay Remote control contact Obstruction for manual on/off Service contact...
Page 140
4.45 CONTROL CIRCUIT—RD400-500-700-850-1000-1200-1600-2000-2400-3000-3800-5000-6000 02250195-307...
Page 141
4.45 CONTROL CIRCUIT—RD400-500-700-850-1000-1200-1600-2000-2400-3000-3800-5000-6000 COMP DESCRIPTION COMP DESCRIPTION F1,F2 Primary protection Drain valve F10,F11 Control circuit protection Remote control alarm contact Control circuit transformer Remote control start button Remote control stop button Thermal protection off-on compressor Compressor heat thermal P10-1 Thermal protection off-on fan 1 P10-2 Thermal protection off-on fan 2 P11-1...
Page 142
4.46 POWER CIRCUIT—RD400-500-700-850-1000-1200-1600-2000-2400-3000-3800-5000-6000 02250195-307...
Page 143
4.46 CONTROL CIRCUIT—RD400-500-700-850-1000-1200-1600-2000-2400-3000-3800-5000-6000 COMP DESCRIPTION Control circuit transformer A30-1/A30-2 Compressor chankaser heaters Main terminal block EMR4 Phase protection relay F1,F2 A01 primary protection Compressor contactor (24V) K10-1 Fan contactor (24V) K10-2 Fan contactor (24V) Water motor M01-1/M01-2 Compressors (400V-440V) M10-1 Fan motor (400V-440V) M10-2 Fan motor (400V-440V)
Page 146
Always air. Always there. WWW.SULLAIR.COM SULLAIR 3700 East Michigan Boulevard • Michigan City, Indiana, 46360 U.S.A. Telephone: 1-219-879-5451 Printed in the U.S.A. Specifications subject to change without prior notice. E12EP...