Section 3 continued
Memory Slot:
Uses Removable Memory for data logging, screen
captures, program loading and recipes.
Horner Part No.: HE-MC1
Serial Communications:
MJ1: (RS-232 / RS-485) Use for Cscape programming and
Application-Defined Communications.
MJ2: (RS-232 / RS-485) Use for Application-Defined
Communications.
Pin
MJ1 Pins
8
TXD
8
7
RXD
6
0 V
Ground
+5
1
5*
60mA
4
RTS
3
CTS
RX- /
2
TX-
RX+ /
1
TX+
* +5Vdc 60mA Max on XLe Rev E and later
4
Wiring and Jumpers
• Wire according to the type of inputs / outputs used and select
the appropriate jumper option. Use Copper Conductors
in Field Wiring Only, 60/75° C
Wiring Specifications
For I/O wiring (discrete), use the
following wire type or equivalent:
2
Belden 9918, 18 AWG (0.8 mm
)
or larger.
For shielded Analog I/O wiring,
use the following wire type or
equivalent: Belden 8441, 18
2
AWG (0.8 mm
) or larger.
For CAN wiring, use the
following wire type or equivalent:
2
Belden 3084, 24 AWG (0.2 mm
)
or larger.
Positive Logic vs. Negative Logic Wiring
The XLE can be wired for Positive Logic inputs or
Negative Logic inputs.
I1
12-24VDC
0V
Positive Logic In
4.1
I/O Jumpers Settings (JP1 – JP3)
Note: The Cscape Module Setup configuration must match
the selected I/O (JP) jumper settings.
JP1 Digital DC Inputs
Positive Logic
Negative Logic
Default
JP3
CURRENT OR VOLTAGE INPUTS
20mA
10VDC
A1
A1
1
2
1
2
A2
A2
3
4
3
4
001XLE043-R1
__________________________________________________________________________________________________________________________________________________________________
4.2
Some XLes have jumpers to set RS-485 port
termination, though most use DIP Switches.
The External Jumpers or DIP Switches are used for
termination of the RS-485 ports. The XLe is shipped
un-terminated.
To terminate, select one of the jumpers shipped with
the product and insert it based upon the option that is
desired or, select the switch (as shown in the
illustration) and configure based upon the option that
is desired.
MJ2 Pins
4.3
OUT
TXD
OUT
Note: The wiring examples show
IN
RXD
IN
Positive Logic input wiring.
0 V
Ground
+5
OUT
OUT
60mA
OUT
TX-
OUT
IN
TX+
OUT
IN /
RX-
IN
OUT
IN /
RX+
IN
OUT
Location of I/O jumpers (JP)
and wiring connectors
(J1 – J4).
J4
Black
JP1
J1
J2
JP3
J3
001XLE005-R1
I1
V+* Supply for Sourcing Outputs
0V
001XLE036
Negative Logic In
Orange
Note:
When using JP3 (A1-A2),
each channel can be
independently configured.
As seen when looking at the top of the XLe unit:
External DIP Switch Settings (or Jumpers Settings)
Wiring Examples
J1
XE103 / XE104
Orange
Name
I1
IN1
I2
IN2
I3
IN3
I4
IN4
I5
IN5
I6
IN6
I7
IN7
I8
IN8
H1
HSC1 / IN9
H2
HSC2 / IN10
H3
HSC3 / IN11
H4
HSC4 / IN12
A1
Analog IN1
A2
Analog IN2
0V
Ground
J2
XE104
XE103
0V
Ground
V+
V+ *
No
OUT13
NC
Connect
Q12
OUT12
Q11
OUT11
Q10
OUT10
Q9
OUT9
Q8
OUT8
Q7
OUT7
Q6
OUT6
Q5
OUT5
Q4
OUT4
Q3
OUT3
Q2
OUT2 / PWM2
Q1
OUT1 / PWM1
J3
XE104
I13
IN13
I14
IN14
I15
IN15
I16
IN16
I17
IN17
I18
IN18
I19
IN19
12-24VDC
I20
IN20
I21
IN21
I22
IN22
I23
IN23
I24
IN24
0V
Ground
Page 2 of 4
DIPSW3: FACTORY
USE ONLY (tiny
bootloader firmware
downloading). NOT TO
BE USED FOR
NORMAL OCS
OPERATION.
DIPSW2: MJ2
Termination
(Default – none)
DIPSW1: MJ1
Termination
(Default – none)
J1 Orange
Positive Logic
Digital In
12-24VDC
20mA
LOOP
PWR
0-10VDC
J2 Black
Positive Logic
Digital Out
0V
10 - 30VDC
V+
Q13
LOAD
J4
Q12
LOAD
Orange
Q11
LOAD
Q16
Q10
LOAD
Q15
Q9
LOAD
Q14
Q8
LOAD
Q7
LOAD
Q6
LOAD
Q5
LOAD
Q4
LOAD
Q3
LOAD
Q2
LOAD
Q1
LOAD
001XLE024
J3 Orange
Positive Logic
Digital In
I13
I14
I15
I16
I17
I18
I19
I20
I21
I22
I23
I24
0V
001XLE047
001XLE037-R1
I1
I2
I3
I4
I5
I6
I7
I8
H1
H2
H3
Note:
Loop Power requirements
H4
are determined by the
A1
transmitter specification.
A2
0V
001XLE046
XE104 J4 Orange
Positive Logic
Digital Out
J2
0V
10 - 30VDC
XE104
V+
J4
OUT16
Q16
LOAD
OUT15
OUT14
Q15
LOAD
Q14
LOAD