Page 30
Firmware Version 4.1 Admin Password:00000000 Admin. Login Successful Configuration Firmware Version 4.1 BD = 9600 (5) PT = odd (1) ST = 1 bit (0) DT = 7 bits (0) MD = RS-485 (1) TO = TT = SLAVE (1) TN = HN = eis1376...
Page 31
Admin. Password:00000000 Admin. Login Successful iServer Configuration Command: cc description pppppp BD BaudRate 0-300,1-600,2-1200,3-2400,4-4800,5-9600,6-19200, 7-38400, 8-57600, 9-115200 PT Parity 0-none,1-Odd,2-even ST StopBits 0-1bits,1-2bits DT DataBits 0-7bits,1-8bits FC FlowControl 0-none,1-XON/XOFF,2-Hardware MD Mode 0-RS232, 1-RS485 MB Modbus/TCP 0-disable, 1-enable TO TimeOut xxxx ms Rang range 100-9999 TU TCP/UDP 0-TCP, 1-UDP TT TerminalType...
Page 33
C:\>arp - 192.168.1.96 No ARP Entries Found C:\>ping 192.168.1.96 Pinging 192.168.1.96 with 32 bytes of data: Reply from 192.168.1.96=bytes=32 time=5ms TTL=32 Reply from 192.168.1.96=bytes=32 time=3ms TTL=32 Reply from 192.168.1.96=bytes=32 time=3ms TTL=32 Reply from 192.168.1.96=bytes=32 time=4ms TTL=32 C:\>arp -a 192.168.1.96 Interface: 192.168.1.118 Internet Address Physical Addresss 192.168.1.96...
Page 47
Note: *Units configured for external low power dc voltage, 12-36Vdc Note: **I/O signal and control lines require shielded cables and these cables must be located on conductive cable trays or in conduits. Furthermore, the length of these cables should not exceed 30 meters...