PG80MSU: Installation, Start-up, Operating and Service and Maintenance Instructions
CAUTION
!
FURNACE RELIABILITY HAZARD
Improper installation or misapplication of furnace may require
excessive servicing or cause premature component failure.
Application of this furnace should be indoors with special attention
given to vent sizing and material, gas input rate, air temperature rise,
unit leveling, and unit sizing.
WARNING
!
FIRE, INJURY, OR DEATH HAZARD
Failure to follow this warning could result in property damage, personal
injury, or death.
Do not bypass any of the safety controls in the furnace, including but
not limited to the main limit switch, rollout or burner thermal switch,
and pressure switch/pressure transducer.
WARNING
!
PERSONAL INJURY AND PROPERTY DAMAGE
HAZARD
Failure to follow this warning could result in property damage, personal
injury, or death.
For continued performance, reliability, and safety, the only approved
accessories and replacement parts are those specified by the equipment
manufacturer. The use of non-manufacturer approved parts and
accessories could invalidate the equipment limited warranty and result
in fire risk, equipment malfunction, and failure. Please review
manufacturer's instructions and replacement part catalogs available
from your equipment supplier
Improper installation, adjustment, alteration, service, maintenance, or
use can cause explosion, fire, electrical shock, or other conditions which
may cause death, personal injury, or property damage. Consult a
qualified installer, service agency, or your distributor or branch for
information or assistance. The qualified installer or agency must use
factory-authorized kits or accessories when modifying this product.
Refer to the individual instructions packaged with the kits or accessories
when installing.
Follow all safety codes. Wear safety glasses, protective clothing, and
work gloves. Have a fire extinguisher available. Read these instructions
thoroughly and follow all warnings or cautions include in literature and
attached to the unit. Consult local building codes, the current editions of
the current edition of National Fuel Gas Code (NFGC) NFPA 54/ANSI
Z223.1 and the current edition of National Electrical Code (NEC) NFPA
70.
Recognize safety information. This is the safety-alert symbol
you see this symbol on the unit and in instructions or manuals, be alert to
the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION.
These words are used with the safety-alert symbol. DANGER identifies
the most serious hazards which will result in severe personal injury or
death. WARNING signifies hazards which could result in personal
injury or death. CAUTION is used to identify unsafe practices which
may result in minor personal injury or product and property damage.
NOTE is used to highlight suggestions which will result in enhanced
installation, reliability, or operation.
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear
appropriate protective clothing, safety glasses and gloves when
handling parts and servicing furnaces.
1. Use only with type of gas approved for this furnace. Refer to the
furnace rating plate.
2. Install this furnace only in a location and position as specified in the
"Location" section of these instructions.
3. Provide adequate combustion and ventilation air to the furnace
space as specified in "Air for Combustion and Ventilation" section.
4. Combustion products must be discharged outdoors. Connect this
furnace to an approved vent system only, as specified in the
"Venting" section of these instructions.
5. Never test for gas leaks with an open flame. Use a commercially
available soap solution made specifically for the detection of leaks
to check all connections, as specified in the "Gas Piping" section.
6. Always install furnace to operate within the furnace's intended
temperature-rise range with a duct system which has an external
static pressure within the allowable range, as specified in the
"Start-Up, Adjustments, and Safety Check" section. See furnace
rating plate.
7. When a furnace is installed so that supply ducts carry air circulated
by the furnace to areas outside the space containing the furnace, the
return air shall also be handled by duct(s) sealed to the furnace
casing and terminating outside the space containing the furnace.
See "Air Ducts" section.
8. A gas-fired furnace for installation in a residential garage must be
installed as specified in the warning box in the "Location" section,
see
Fig.
6.
9. The furnace is not permitted to be used for heating of buildings
under construction.
10. These Multipoise Gas-Fired Furnaces are CSA (formerly A.G.A.
and C.G.A). design-certified for use with natural gas (see furnace
rating plate) and for installation in alcoves, attics, basements,
closets, utility rooms, crawlspaces, and garages. The furnace is
factory-shipped for use with natural gas and cannot be converted to
propane gas.
11. See
Fig. 2
for required clearances to combustible construction.
12. Maintain a 1-in. (25 mm) clearance from combustible materials to
supply air ductwork for a distance of 36 inches (914 mm)
horizontally from the furnace. See current edition of NFPA 90B or
local code for further requirements.
13. These furnaces SHALL NOT be installed directly on carpeting, tile,
or any other combustible material other than wood flooring. In
downflow installations, factory accessory floor base MUST be used
. When
when installed on combustible materials and wood flooring. Special
base is not required when this furnace is installed on manufacturer's
approved coil assembly or a manufacturer's coil casing box is used.
See
Fig. 2
for clearance to combustible construction.
3
CAUTION
!