Motor Rotation Check - Sullair LS-25S-257KW Operator's Manual And Parts List

Industrial rotary screw air compressor
Table of Contents

Advertisement

starter. Pull out the EMERGENCY STOP button
on the control panel. Depress the PROG pad
twice to get to AUTOMATIC/MANUAL mode se-
lection and use the cursor pad to change to
MANUAL mode.
5. Reconnect the three (3) motor leads and jog the
motor for a direction of rotation check, as ex-
plained in Section 4.8.

4.8 MOTOR ROTATION CHECK

After the electrical installation has been done, it is
necessary to check the direction of motor rotation.
INSTALLATION
Pull out the EMERGENCY STOP button and press
once, quickly and in succession, the (START) I and
(STOP) O pads. This action will bump start the mo-
tor for a very short time. When looking at the motor
rear end, the driveline should be rotating in the di-
rection indicated by the "Direction of Rotation" de-
cal located on the top of the compressor/motor
adapter piece. If the reversed rotation is noted, dis-
connect the power to the starter and exchange any
two of the three power input leads, then re---check
rotation. A "Direction of Rotation" decal is located
on the top of the compressor/motor adaptor piece.
Section 4
21