SAFETY PRECAUTIONS This device is to be serviced only by properly qualified service personnel. Consult the service manual for proper service procedures to assure continued safety operation and for precautions to be taken to avoid possible exposure to excessive microwave energy. PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY...
SPECIFICATIONS ITEM DESCRIPTION MODEL MH-706CL Power Requirement 240 Volts AC 50 Hz Single phase, 3 wire grounded Microwave 1,400W Grill 1,300W Combination 2,600W Power Output 900 Watts full microwave power (IEC705) Microwave Frequency 2,450 MHz Magnetron 2M214 - 39F Timer 99 min.
CAUTIONS Unlike other appliances, the microwave oven is MICROWAVE RADIATION high-voltage and high-current equipment. Personnel should not be exposed to the Though it is free from danger in ordinary use, microwave energy which may radiate from the extreme care should be taken during repair. magnetron or other microwave generating device if it is improperly used or connection.
INSTALLATIONS BEFORE YOU BEGIN, READ THE FOLLOWING INSTRUCTIONS COMPLETELY AND CAREFULLY. INSTALLING EARTHING INSTRUCTIONS 1. Empty the microwave oven and clean inside it with This microwave oven is designed to be used in a fully a soft, damp cloth. Check for damage such as earthed condition.
OPERATING INSTRUCTIONS FEATURES Oven front face Window door screen Door seal Display Window Control panel Safety Door Lock System Grill Rack Glass Tray Rotating Ring CONTROL PANEL 1. POWER: Used to select the desired power level for cooking. 2. COMBI: Used to select the combination cooking. 3.
OPERATING SEQUENCE The following is a description of component functions 6. GRILL COOKING during oven operation. Desired Stop Grill Start 1. SETTING THE CLOCK cooking time Set the Stop 7. COMBINATION COOKING clock clock correct time Desired NOTE: You can set 12 hour clock or 24 hour clock Desired Stop combi...
CIRCUIT DESCRIPTION power of microwave oven as POWER LEVEL. GENERAL DETAILS (refer to page 1-1) • The low voltage transformer supplies the necessary • One complete cycle of relay 2 is 22 seconds. voltage to the micom controller when power cord is plugged in.