•
Auto Fan Speed during cooling operation:
1
Indoor fan will rotate alternately between off and on as shown in below diagram.
2
At the beginning of each compressor starts operation, indoor fan speed increases gradually for deodorizing
purpose.
3
For the first time the compressor operates, indoor fan will be switched to Hi fan speed from Lo- after 70
seconds from the start of compressor. This cause the room temperature to achieve the setting temperature
quickly.
4
During compressor stops, indoor fan will operate at Lo- for the beginning 20 seconds to prevent higher
volume of refrigerant in liquid form returning to the compressor.
5
After the compressor turned off for 3 minutes, indoor fan will start to operate at Lo- to circulate the air in the
room. This is to obtain the actual reading of the intake air temperature.
6
For the resume of compressor operation, indoor fan will operate at Me fan speed to provide comfort and
lesser noise environment, after 70 seconds from the restarts of compressor.
•
Auto Fan Speed during Soft Dry operation.
Indoor fan will rotate alternately between off and Lo-.
o
At the beginning of each compressor starts operation, indoor fan will increase fan speed gradually for
o
deodorizing purpose.
When compressor turned off for 6 minutes, indoor fan will start at Lo- to circulate the air in the room. This is
o
to obtain the actual reading of intake air temperature.
56