Auto shutter

The brightness of image maintains to keep target brightness with shutter automatically.
If the brightness of image is darker than target brightness, exposure time extends up to
"ExposureAutoLimitMax".
If the brightness of image is brighter than target brightness, exposure time becomes shorter up to
"ExposureAutoLimitMin".
GenICam Parameters
ExposureAuto
ExposureAutoLimitMin
ExposureAutoLimitMax

ALC settings procedure

ALC Settings Procedure
1. Sets "AutoLuminanceWidth", "AutoLuminanceHeight", "AutoLuminanceOffsetX",
"Aut LuminanceOffsetY" and "AutoLuminanceWeight" for "AutoLuminanceRegion0 to 8".
2. Sets "Continuous" for "GainAuto" when using AGC function.
3. Sets "GainAutoLimitMin" and "GainAutoLimitMax" when using AGC function.
4. Sets "Continuous" for "ExposureAuto" when using auto shutter function.
5. Sets "ExposureAutoLimitMin" and "ExposureAutoLimitMax" when using auto shutter function.
6. Sets "Auto Luminance Target".
STC-LBS132POE-SWIR
Product Specifications and User's Guide
IEnumeration Type
Auto shutter ON / OFF selection
Selection: "ON" (Continuous), "OFF" (Off)
Default: "OFF"
IFloat Type
Minimum exposure time (in µsecond) for auto shutter
Range: 8 to 16,777,215
Default: 8
IFloat Type
Maximum exposure time (in µsecond) for auto shutter
Range: 8 to 16,777,215
Default: 11,749