Exposure Timing With Positive Polarity Trigger Signal - Omron STC-LBS132POE-SWIR Product Specifications And User's Manual

Gige vision swir cmos poe camera
Table of Contents

Advertisement

Exposure Timing with Positive Polarity Trigger Signal

Trigger signal
(Positive polarity)
Trigger signal with
camera internal delay
Exposure time
Note 1: The trigger signal will be removed by filtering if active pulse width of input trigger signal is less than
"LineDebounceTime" setting time. Please input trigger signal has more than "LineDebounceTime" time
active pulse width trigger signal.
Note 2: Please refers "External Hardware Trigger Input Delay" for more details about "External hardware trigger
delay".
STC-LBS132POE-SWIR
Product Specifications and User's Guide
Debounce
Tdelay
*Note 1
*Note 2
Mono8, Mono10: 1H = 9.428 µseconds
Exposure time: T1' = Preset Exposure Time setting
0 to 1H
No.21S102-02
Mono12: 1H = 13.091 µseconds
T1'