Select Installation Location - Qlima S-6035 Operating Manual

Hide thumbs Also See for S-6035:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 90
lnstallation lnstructions - Outdoor Unit
Step 1: Select installation location
Before installing the outdoor unit, you must choose an appropriate location. The following are standards
that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Meets all spatial requirements shown in lnstallation Space Requirements above.
Good air circulation and ventilation
Firm and solid - the location can support the unit and will not vibrate
Noise from the unit will not disturb others
Protected from prolonged periods of direct sunlight or rain
Where snowfall is anticipated, raise the unit above the base pad to prevent ice buildup and coil
damage. Mount the unit high enough to be above the average accumulated area snowfall.
The minimum heigh must be 18 inches
DO NOT install unit in the following locations:
Near an obstacle that will black air inlets and outlets
Near a public street, crowded areas, or where noise from the unit will disturb others
Near animals or plants that will be harmed by hot air discharge
Near any source of combustible gas
In a location that is exposed to large amounts of dust
In a location exposed to a excessive amounts of salty air
SPECIAL CONSIDERATIONS FOR EXTREME WEATHER
lf the unit is exposed to heavy wind:
lnstall unit so that air outlet fan is at a 90° angle to the direction of the wind. lf needed, build a barrier in
front of the unit to protect it from extremely heavy winds.
See Figures below.
Strong wind
lf the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or snow. Be careful not to obstruct air
flow around the unit.
lf the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist corrosion.
Step 2: lnstall drain joint(Heat pump unit only)
Before bolting the outdoor unit in place, you must install the drain joint at the bottom of the unit. Note
that there are two different types of drain joints depending on the type of outdoor unit.
4
120
man_S60xx SCAN ('21) V4.indd 120
man_S60xx SCAN ('21) V4.indd 120
Strong wind
Wind Baffle
Strong wind
09-11-2021 09:07
09-11-2021 09:07

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-60 series

Table of Contents