Select Installation Location; Attach Mounting Plate To Wall - Qlima S65 Series Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 90
Step 1: Select installation location
Before installing the indoor unit, you must choose an appropriate location. The following are
standards that will help you choose an appropriate location for the unit.
Proper installation locations meet the following standards:
Good air circulation
Convenient drainage
Noise from the unit will not disturb other people
Firm and solid-the location will not vibrate
Strong enough to support the weight of the unit
A location at least one meter from all other electrical devices (e.g., TV, radio, computer)
DO NOT install unit in the following locations:
Near any source of heat, steam, or combustible gas
Near flammable items such as curtains or clothing
Near any obstacle that might black air circulation
Near the doorway
In a location subject to direct sunlight
G
NOTE ABOUT WALL HOLE
lf there is no fixed refrigerant piping:
While choosing a location, be aware that you should leave ample room for a wall hole (see Drill
wall hole for connective piping step) for the signal cable and refrigerant piping that connect the
indoor and outdoor units. The default position for all piping is the right side of the indoor unit
(while facing the unit). However, the unit can accommodate piping to bath the left and right.
Refer to the following diagram to ensure proper distance from walls and ceiling:
12cm (4.75in) or more
Step 2: Attach mounting plate to wall
The mounting plate is the device on which you will mount the indoor unit.
Remove the screw that attaches the mounting plate to the back of the indoor unit.
Secure the mounting plate to the wall with the screws provided. Make sure that mounting plate is
flat against the wall.
G
NOTE FOR CONCRETE OR BRICK WALLS
lf the wall is made of brick, concrete, or similar material, drill 5mm-diameter (0.2in-diameter)
holes in the wall and insert the sleeve anchors provided. Then secure the mounting plate to the
wall by tightening the screws directly into the clip anchors.
4
112
man_S60xx SCAN ('21) V4.indd 112
man_S60xx SCAN ('21) V4.indd 112
15cm (5.9in) or more
2.3m 90.55in) or more
12cm (4.75in) or more
09-11-2021 09:07
09-11-2021 09:07

Advertisement

Table of Contents
loading

This manual is also suitable for:

S60 seriesS6035

Table of Contents