16 en | Introduction
Fig. 3.2 The AMC2 4W in a four door safety lock
The AMC2 4W can communicate upstream to the host computer
via eight RS-485 multi-dropped, RS-232 or 10/100 Mbit/s Ether-
net. It has eight analog input devices and eight relay outputs.
With its analog input devices, the AMC2 4W verifies, for exam-
ple, if a lock is closed or open. The relay outputs can be used to
activate lock mechanisms if access is granted, or activate an
external alarm system if an intrusion or system alert is
detected. If the eight input and output on board are not enough
to configure the system up to three additional extensions (AMC
8I-8O or AMC 16I-16O) can be connected. The extensions offer
8 or 16 additional inputs and outputs.
The setup procedure for an AMC2 4W is very simple and
extremely fast by the use of door templates. Once selected, all
the inputs and outputs are predefined. This settings can be
changed using the Device Editor in that way to choose every
free contact of the AMC2 4W or an connected extension.
F.01U.024.965 | V 0.1 | 2006.03