  • Page 1 AE-237 Outdoor Enclosure Installation Guide Rev. 1.1 Ordering part no.: 900026900G AE-237_V01 Document part no.: 625030701G IP Sur veillance...
  • Page 2: Specifications

    3.5 A Heater Control 15°C (ON) / 25°C (OFF) Blower Control 35°C (ON) / 25°C (OFF) Environmental Operation Temp. AE-237 Single heater: -20°C ~ +50°C When temperature reaches -10°C, camera is powered on) Protection Level IP66, IK10 Temper Glass thickness...
  • Page 3: Mounting Configuration & Dimensions

    Mounting Configuration & Dimensions Swivel Positions and Directions 462.7 Component Description Circulation Heater Waterproof cable Heater for the dual-heater, gland -40ºC model Power Supply Unit...
  • Page 4: Installation Suggestions

    Installation Suggestions If you plan to install this camera enclosure into a tropical, sea coastal, or an environment where salt water or corrosive industrial waste water/moist are present, please seal each stainless steel screws and fittings with a silicon grease compounds. This will help prevent electrolysis to occur and extend the life span of the camera and housing.
  • Page 5 You may need to remove the RJ45 connector, and use a crimping tool to connect the Ethernet wires to an RJ45 connector inside the enclosure. Use an Ethernet cable of the width of 5 ~ 6.5mm. o: white/orange stripe O: orange solid g: white/green stripe B: blue solid b: white/blue stripe...
  • Page 6 If preferred, you can install external IR lights and route IR light power and signal wires through the two waterproof cable glands in the front. Pass the IR light units' signal wires through the waterproof connectors on the front. Check the inside of the enclosure to make sure the I/O wires can reach the power supply unit inside.
  • Page 7 Assemble the camera components, e.g., the CS ring and lens module. If using the IP816A-HP camera, align the buffer pad with the mounting hole at the bottom of the camera (the label side). Place the mounting plate on top of the buffer pad and then secure it to the camera. You may need adjust its position so that the lens module can flush align with the tempered glass.
  • Page 8 Attach the AC24V power wires and power inputs from the IR light units to the terminal connector. Connect the power wires from IR units to the terminal. Since AC 24V is polarity free, Connect AC 24V from outer source, 24V inputs for IR (2 pairs), and 24V inputs for camera, all to the same terminal connector.
  • Page 9 Having the wiring done inside the enclosure, you can install the enclosure bracket to a preferred location at your installation site. Drill mounting holes and a cable routing hole (if preferred) on a wall. Install the bracket. Lift the whole enclosure up to the installation position, and pass the 24V power wire and the Ethernet cables through the bracket.
  • Page 10 Mount the enclosure on to the installed bracket, and secure the connection by tightening the 4 socket screws. Due to the weight of the enclosure, it is best to have two men mounting the enclosure. Adjust zoom and focus and open a web session with the camera to tune for the best image.
  • Page 11 Optional Installation: Ethernet-to-fiber optic converter The fiber converter comes with a DIN-rail bracket. Install the converter module to the metal bracket simply by sliding it into place. Connect two power wires to the AC terminal block. Since AC 24V is polarity free, connect AC 24V from outer source and 24V input for the module, all to the same terminal connector.
  • Page 12 This page is intentionally left blank.