Install the Door Control

Locate door control within sight of the door at a
minimum height of 5 feet where small children cannot
reach, and away from moving parts of the door and
door hardware. If installing into drywall, drill 5/32"
holes and use anchors provided. For pre-wired
AVERTISSEMENT
installations (as in new home construction), it may be
mounted to a single gang box. NOTE: After
installation, a green indicator light behind the cover will
indicate proper connection. If not lit, the Lock and Light
ATTENTION
features will not function (reverse wires to correct).
1. Strip 1/4" of insulation from one end of bell wire and
connect to the two screw terminals on back of door
control by color: white wire to 2 and white/red wire to 1.
2. Lighted door control: Fasten to wall with 6ABx1-1/2"
self-tapping screws.
Multi-function door control:
gently pushing both thumbs against upper corners of
cover on back side of door control. Fasten with
6ABx1-1/4"self-tapping screws (standard installation)
or 6-32x1" machine screws (into gang box) as
follows:
• Drill and install bottom screw, allowing 1//8" to
protrude above wall surface.
• Position bottom of door control on screw head and
slide down to secure. Adjust screw for snug fit.
• Install top screw with care to avoid cracking plastic
housing. Do not overtighten.
• Insert bottom tabs and snap on cover. (To remove
cover after mounting, gently pry at top with paper
clip or small flat head screwdriver.)
3. (Standard installation only) Run bell wire up wall
and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do not
pierce wire with a staple, creating a short or open
circuit.
4. Connect bell wire to the opener terminal screws as
follows: white to 2 and white/red to 1.
5. Use tacks or staples to permanently attach
entrapment warning label to wall near door control,
and manual release/safety reverse test label in a
prominent location on inside of garage door.
NOTE: DO NOT connect the power and operate the
opener at this time. The trolley will travel to the full
open position but will not return to the close position
until the sensor beam is connected and properly
aligned. See Safety Reversing Sensor Instructions
beginning on page 21.
HARDWARE SHOWN ACTUAL SIZE
6ABx1-1/2" Screw
Lighted Door Control Button
6AB x 1-1/4" Screw
Multi-function (std installation)
Remove white cover by
Insulated
Staples
6-32 x 1" Screw
Dry Wall
Multi-function (pre-wired)
Anchors
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of
reach of children at a minimum height of 5 feet, and
away from all moving parts of door.
• NEVER permit children to operate or play with door
control push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYS keep garage door in sight until completely
closed. NEVER permit anyone to cross path of closing
garage door.
REMOVE COVER
RED WHT
1
PRE-WIRED INSTALLATION
To Replace,
Insert Bottom Tabs First
Series 3200HBC
Bell Wire
LIGHTED
DOOR CONTROL
MULTI-FUNCTION
BUTTON
DOOR CONTROL PANEL
18
WARNING
WARNING
AVERTISSEMENT
AVERTISSEMENT
STANDARD WALL MOUNT
To Replace,
Insert Bottom Tabs First
24 Volt
2-Conductor Bell Wire
Terminal
Screws
RED WHT
1
Series
5200HBC
Opener Terminal Screws
Push
Bar
Lock
BACK PANEL
Button
Light
Button
1
2
3
9
1
9
1
7
3
7
3
5
5
KG
KG
Antenna

Advertisement

Table of Contents
loading

This manual is also suitable for:

Security+ 5200hbc series

Table of Contents