Download Print this page

Kohler Memoirs K-724-G96 Installation Instructions page 2

60" x 33-3/4" alcove bubblemassage air bath

Advertisement

No change in measurements if connected
with drain illustrated. (K-7161-AF)
NOTE: Blower protrusion
beyond the rim.
Blower Motor/Control Access
34" (864 mm) W x
15" (381 mm) H
33-3/4" (857 mm)
17-7/16"
(443 mm)
Required Electrical Service
One dedicated circuit required, protected with Class A Ground-
Fault Circuit-Interrupter (GFCI). Outside North America, this
device may be known as a Residual Current Device (RCD).
Blower:
240 V, 15 A, 50/60 Hz
Technical Information
All product dimensions are nominal.
Installation:
Three-wall alcove
Drain location:
Right
Basin area, bottom:
45" x 23" (1143 mm x 584 mm)
Basin area, top:
54" x 25" (1372 mm x 635 mm)
Weight:
390 lbs (176.9 kg)
Minimum floor load:
61 lbs/ft² (297.8 kg/m²)
Water depth:
11-5/8" (295 mm)
Water capacity:
52 gal (196.8 L)
Electrical component
Blower: 240 V, 5 A, 50/60 Hz
rating:
Blower speed:
Variable
1-800-4KOHLER (1-800-456-4537)
Kohler Co. reserves the right to make revisions without notice to product specifications.
For the most current Specification Sheet, go to www.kohler.com.
7-30-2022 00:37 - US/CA
1" (25 mm)
1-1/2"
Bath Drain
60" x 33-3/4" alcove BubbleMassage
60" (1524 mm)
1-13/16" (46 mm)
Lumbar
Angle 31°
1/8" (3 mm)
Notes
Measure your actual product for rough-in
details.
Install this product according to the installation
instructions.
The hot water supply should be 70% of the
capacity of the bath or greater. Installations will
vary.
If relocating the blower motor, do not relocate
or alter the PVC tee or coiled flexible tubing
connected to the blower. Follow the blower
relocation instructions exactly. Provide access
for servicing the blower.
ADA compliant when installed to the specific
requirements of these regulations.
Memoirs
air bath
K-724-G96
1-1/2"
(38 mm)
16"
(406 mm)
32"
(813 mm)
8-1/2" (216 mm)
3-1/4"
(83 mm)
2-7/8"
(73 mm)
3"
(76 mm)
®

Advertisement