The following is a list of error log IDs.
AA: BE0 attention line did not get high in step 1
AB: BE1 attention line did not get high in step 1
AC: BE0 attention line did not get high in step 2
AD: BE1 attention line did not get high in step 2
AE: BE0 attention line did not get high in step 3
AF: BE1 attention line did not get high in step 3
AG: BE0 attention line did not get high in step 4
AH: BE1 attention line did not get high in step 4
AI: BE0 attention line did not get high in step 5
AJ: BE1 attention line did not get high in step 5
AK: BE0 Poll 1 did not return expected value
AL: BE1 Poll 1 did not return expected value
AM: BE0 Poll 2 did not return expected value
AN: BE1 Poll 2 did not return expected value
AO: BE0 Poll 3 did not return expected value
AP: BE1 Poll 3 did not return expected value
AQ: BE0 Poll 4 did not return expected value
AR: BE1 Poll 4 did not return expected value
AS: BE0 Poll 5 did not return expected value
AT: BE1 Poll 5 did not return expected value
AU: BE0 VID value that is read out is not valid
AV: BE1 VID value that is read out is not valid
AW: BE0 Poll 7 did not return expected value
AX: Hardware revision read from the VPD is not supported or invalid
AY: SB0 UART request did not return expected value
AZ: SB1 UART request did not return expected value
BA: BE0 does not request configuration data
BB: BE1 does not request configuration data
BC: BE0 does not request RRAC training
BD: BE1 does not request RRAC training
BE: BE0 does not request bus credentials
BF: BE1 does not request bus credentials
BG: BE0 still needs attention after init procedure is is done
BH: BE1 still needs attention after init procedure is is done
BI: BE0 RRAC training failed
BJ: BE1 RRAC training failed
BK: BE0 IOC init failed
BL: BE1 IOC init failed
BM: BE thermal alert from temperature monitor ADT7467
BN: BE0 thermal alert pin goes high
BO: BE1 thermal alert pin goes high
BP: BE0 TX_PLL status not correct during RRAC BE to BE init
BQ: BE1 TX_PLL status not correct during RRAC BE to BE init
BR: BE0 RX_PLL status not correct during RRAC BE to BE init
BS: BE1 RX_PLL status not correct during RRAC BE to BE init
BT: BE0 RX status not correct during RRAC BE to BE cal (bit training)
BU: BE1 RX status not correct during RRAC BE to BE cal (bit training)
BV: BE0 RX status not correct during RRAC BE to BE cal (parallel and slice)
BW: BE1 RX status not correct during RRAC BE to BE cal (parallel and slice)
BX: BE0 RX status not correct during RRAC BE Byte training
BY: BE1 RX status not correct during RRAC BE Byte training
CA: BE0 RX status not correct during cw_rracup_sb_hr RRC0
CB: BE1 RX status not correct during cw_rracup_sb_hr RRC1
CI: BE0 RX status not correct during RRAC SB Byte training
CJ: BE1 RX status not correct during RRAC SB Byte training
CK: BE0 RX4 phase cal status not correct during SB0 bit training
CL: BE1 RX4 phase cal status not correct during SB1 bit training
CM: SB0 RX0 phase cal status not correct during SB0 bit training
CN: SB1 RX0 phase cal status not correct during SB0 bit training
CO: BE0 RX4 parallel and slice cal status not correct during SB0 bit training
24
BladeCenter QS20 Type 0200: Problem Determination and Service Guide
D0: No response from clock device XCG0 (BE PLL)
D1: No response from clock device XCG1 (RC)
D2: No response from clock device XCG2 (Y)
DA: No response from an unknown clock device