User manual
3
Configuration
To configure the Dongle, follow the steps below.
Connect the Dongle to a supply, either a wired bus or to 24 V DC, run the wM-Bus application,
and click the [Run the WIRELESS Application] button (see Figure 2)
Search for wM-Bus meters (see Figure 2)
Choose the wM-Bus meters (see Figure 2)
Configure the wired M-Bus address etc. (see Figure 3)
Store the configuration (see Figure 3).
Note: In Figures 2 and 3, all fields marked with red must be filled in.
The menu tabs of the software are described in the following paragraphs.
3.1
Main tab
Choose application: Select the interface to use, wired or wireless. If wired application is used,
remember to connect an M-Bus to the serial/USB converter, e.g. a Kamstrup MBM 250D. If the
wireless application is used, remember to connect the USB Tool to the PC. Drivers for this USB Tool
are normally found by the operating system.
wM-Bus Dongle SW Tool
Figure 2
4