Appendix C: Flonidan Rev. B meter set-up

If the option board (radio module) in the meter is an old Flonidan Revision B type, the set-up should
be as follows:
Transfer the data from the Main tab, or enter the METER ADDRESS manually.
Set the options as shown, i.e. tick the checkboxes Meter enabled, 2-way radio, Rev B
compatible and Meter data valid (Options in hex = 23).
If the meter is not installed, set the Meter Install state to 255. Next time the meter sends out an
ACCESS DEMAND INSTALL STATE (Ci=0x06), the Dongle will acknowledge this, and the state will
change to 1 when seeing the next message from the meter.
Set Meter M-Bus address to where you want the meter to respond on the M-Bus.
T1 period and T2 fraction cannot be set.
IEK and KEY are not used.
Set the Rev B barcode. As this is not included in the radio message, the Dongle will add this to
the wired M-BUS REQ_UD2 response.
The Option Board data fields are not used.
wM-Bus Dongle SW Tool
Figure 10
13