IMPoRtANt SAFEtY INFoRMAtIoN

NOTE TO INSTALLER: Please read all instructions
before servicing this equipment. Pay attention to all safety
warnings and any other special notes highlighted in the
manual.
Safety markings are used frequently throughout this
manual to designate a degree or level of seriousness and
should not be ignored. WARNING indicates a potentially
hazardous situation that if not avoided, could result in
personal injury or death. cAutIoN indicates a potentially
hazardous situation that if not avoided, may result in minor
or moderate injury or property damage.
WARNING:
ELEctRIcAL SHocK, FIRE oR EXPLoSIoN
HAZARD
Failure to follow safety warnings exactly could
result in serious injury or property damage.
Improper servicing could result in dangerous
operation, serious injury, death or property
damage.
• Before servicing, disconnect all electrical power
to air handler.
• When servicing controls, label all wires prior
to disconnecting. Reconnect wires correctly.
• Verify proper operation after servicing.

GENERAL INFoRMAtIoN

Requirements & codes
WARNING:
this unit must be installed in accordance with
instructions outlined in this manual during
the installation, service, and operation of
this unit. unqualified individuals should not
attempt to interpret these instructions or
install this equipment. Failure to follow safety
recommendations could result in possible
damage to the equipment, serious personal
injury or death.
• The installer must comply with all local codes and
regulations which govern the installation of this type
of equipment. Local codes and regulations take
precedence over any recommendations contained in
these instructions. Consult local building codes for
special installation requirements.
• This equipment contains nitrogen gas. Installation or
servicing should only be performed by qualified trained
personnel thoroughly familiar with this type equipment.
• All electrical wiring must be completed in accordance
with local, state and national codes and regulations
and with the National Electric Code (ANSI/NFPA 70) or
and HUD Manufactured Home Construction and Safety
Standard, Title 24 CFR, Part 3280. If this standard
is not applicable, the installation must be comply to
the Standard for Manufactured Home Installation
Manufactured Home Sites, Communities and Setups
(ANSI 225.1). In Canada all electrical wiring must be
completed in accordance with the Canadian Electric
Code Part 1 CSA C.22.1
• Installation of equipment may require brazing operations.
Installer must comply with safety codes and wear
appropriate safety equipment (safety glasses, work
gloves, fire extinguisher, etc.) when performing brazing
operations.
• Install this unit only in a location and position as
specified on page 4. This unit is designed only for Indoor
installations and should be located with consideration
of minimizing the length of the supply and return ducts.
Refer to the rating plate or Tables 6a & 6b (page 17) for
proper circulating airflow data.
• Follow all precautions in the literature, on tags, and
on labels provided with the equipment. Read and
thoroughly understand the instructions provided with
the equipment prior to performing the installation and
operational checkout of the equipment.

About the Air Handler

This appliance has been tested and certified by AHRI for
capacity and efficiency and will provide many years of safe
and dependable comfort, providing it is properly installed
and maintained. Abuse, improper use, and/or improper
maintenance can shorten the life of the appliance and
create unsafe hazards. Please read all instructions before
installing the unit.
The B6BV Series electric furnace is approved for use
in HUD code manufactured homes (HUD Manufactured
Home Construction and Safety Standard (Title 24, Part
3280) and other modular home applications
B6BV Series electric furnaces are supplied with factory
installed electric heat. Approved NORDYNE heat-pump/
air conditioning coils may be installed in the field. Unless
otherwise noted in the instructions, only factory authorized
kits or accessories may be used when modifying this
product.

Mounting Applications

Vertical only air handlers are factory ready for upflow
applications. These units may also be applied in downflow
discharge applications when applied with the appropriate
field kit.
Through-the-floor installations require a 1/4" thick
noncombustible resilient gasket to be used whenever the
supply or return air ducts pass through the floor. The gasket
should be positioned between the duct, unit, and floor.
3