Figure 19. Units with UC400 controls and ECM motors –
DIP switch settings
Table 13. PSC blower motor external static pressure without return air door (RAD) with filter
Model
(a)
Speed
Ducted
Tap
Unit
High
Yes
Low
Yes
GET009
High
No
Low
No
High
Yes
Low
Yes
GET012
High
No
Low
No
High
Yes
Low
Yes
GET015
High
No
Low
No
High
Yes
Low
Yes
GET018
High
No
Low
No
High
Yes
Low
Yes
GET024
High
No
Low
No
High
Yes
Low
Yes
GET036
High
No
Low
No
Model
Speed
Ducted
Tap
Unit
High
Yes
Low
Yes
GET012
High
No
Low
No
WSHP-SVX10H-EN
External Static Pressure (in. of wg)
CFM
0
Max
Min
CFM
KW
408
421
0.108
355
0.073
357
0.073
272
307
0.061
453
453
0.140
401
0.112
418
0.125
304
345
0.097
648
560
0.155
553
0.169
432
445
0.135
780
665
0.253
696
0.361
520
544
0.271
984
908
0.344
850
0.317
656
799
0.292
1404
1303
0.651
1330
0.642
936
1059
0.523
External Static Pressure (in. of wg)
CFM
0.30
Max
Min
CFM
KW
453
316
0.121
286
0.107
304
Installations at altitudes above 2000 feet may require an
adjustment to the fan speed setting to achieve the proper
airflow. To adjust the airflow to get the desired CFM, set the DIP
switches located in the control box to the proper profile setting.
®
Tracer
TU can be used to make further adjustments to the fan
speed.
Use the following table to select the correct profile to use.
Table 12. Profiles for altitude range
Profile
A
B
C
D
0.05
0.10
CFM
KW
CFM
KW
388
0.107
354
0.106
332
0.072
307
0.070
333
0.071
309
0.070
297
0.060
280
0.059
433
0.137
412
0.134
383
0.109
362
0.106
400
0.122
379
0.120
331
0.095
313
0.092
652
0.191
539
0.153
523
0.152
538
0.167
524
0.165
433
0.135
422
0.134
644
0.249
625
0.246
675
0.354
654
0.348
526
0.266
506
0.262
895
0.335
876
0.327
827
0.310
806
0.303
781
0.286
764
0.280
1293
0.638
1282
0.625
1304
0.630
1277
0.618
1051
0.516
1042
0.510
0.35
0.40
CFM
KW
CFM
KW
288
0.118
Altitude (Feet)
0–2000
2000–4000
4000–6000
Above 6000
0.15
0.20
CFM
KW
CFM
KW
320
0.104
283
0.103
278
0.068
245
0.067
282
0.069
253
0.067
258
0.058
390
0.130
367
0.127
340
0.103
318
0.100
356
0.117
332
0.113
292
0.090
634
0.187
616
0.183
511
0.149
499
0.146
510
0.162
496
0.159
608
0.242
592
0.237
632
0.342
610
0.336
854
0.318
829
0.310
787
0.297
768
0.291
746
0.275
727
0.269
1270
0.614
1256
0.603
1248
0.606
1219
0.593
1033
0.503
1022
0.496
0.45
0.50
CFM
KW
CFM
KW
Installation
0.25
CFM
KW
244
0.102
342
0.124
295
0.097
309
0.110
598
0.179
487
0.143
481
0.155
575
0.232
588
0.330
988
0.402
803
0.301
750
0.286
709
0.264
1240
0.592
1188
0.581
1011
0.488
0.55
CFM
KW
21