Mitsubishi Electric MELSERVO-J2S Series Transition Handbook page 189

Servo amplifiers & motors
Hide thumbs Also See for MELSERVO-J2S Series:
Table of Contents

Advertisement

Part 5: Review on Replacement of MR-J2S-30 kW or Higher Capacity Models with MR-J4-DU_
(c) General-purpose interface 400 V class
Here are described settings of drive unit specific parameters. Settings of the other parameters are the
same as MR-J4-_A_. Refer to Chapter 5 of "MR-J4-_A_(-RJ) Servo Amplifier Instruction Manual".
MR-J2S-_A4
No.
Name and function
0
Control mode and regenerative option selection
0
0
0
0
Refer to the MR-J2S-_A_ servo amplifier
Instruction Manual.
Regenerative option selection
Make sure to set "0".
17
Analog monitor output
0
0
0
Setting
Analog monitor 2 (MO2) Analog monitor 1 (MO1)
value
0
Servo motor speed (±8 V/max. speed)
1
Torque (±8/max. torque)
2
Servo motor speed (±8 V/max. speed)
3
Torque (±8/max. torque)
4
Current command (±8 V/max. current command)
5
Speed command (±8/max. speed)
6
Droop pulse (±10 V/128 pulse)
7
Droop pulse (±10 V/2048 pulse)
8
Droop pulse (±10 V/8192 pulse)
9
Droop pulse (±10 V/32768 pulse)
A
Droop pulse (±10 V/131072 pulse)
B
Bus voltage (+8 V/800 V)
Note 1. "Maximum speed" and " Maximum torque" differ depending on the servo motor. Therefore, after the existing motor has been
replaced with an HG motor, the output voltage for "Maximum speed" or " Maximum torque" may differ.
2. Units used for MR-J2S-_A_ are different from those for MR-J4-_A_. Note that the input range of existing equipment needs to
be adjusted.
3. Set "0008" or "0009". When setting the value, note that the input range of existing equipment needs to be adjusted.
(d) SSCNET interface 400 V class
Initial
value
0000h
0100h
POINT
Connecting to a servo system controller writes servo parameters of the controller
into the corresponding parameters of the drive unit.
There are some servo system controller models, drive unit software versions, or
MR Configurator2 software versions which limit setting of some parameters or
setting values of the parameters. For details, refer to servo system controller
user's manuals.
No.
PA02
Regenerative options
Select a regenerative option.
For a drive unit, select a regenerative option by
configuring the converter unit.
Select "_ _ 0 0" or "_ _ 0 1", otherwise [AL. 37 Parameter
error] will occur.
00: Use no regenerative option, or use a regenerative
option by configuring the converter unit.
PC14
Analog monitor output
PC14/PC15
0000
0001
0002
0003
0004
0005
PC15
0006
0007
0008
0008 or 0009
0009
000D
5 - 28
MR-J4-_A4
Name and function
Display definition
Servo motor speed
(±8 V/max. speed) (Note 1)
Torque
(±8 V/max. torque) (Note 1)
Servo motor speed
(±8 V/max. speed) (Note 1)
Torque
(+8 V/max. torque) (Note 1)
Current command
(±8 V/max. current command)
Command pulse frequency
(±10 V/4 Mpulses/s) (Note 2)
Servo motor-side droop pulses
(±10 V/100 pulses) (Note 2)
Servo motor-side droop pulses
(±10 V/1000 pulses) (Note 2)
Servo motor-side droop pulses
(±10 V/10000 pulses) (Note 2)
(Note 2, 3)
Servo motor-side droop pulses
(±10 V/100000 pulses) (Note 2)
Bus voltage (+8 V/400 V)
Initial
value
0000h
0000h
0001h