Section 3 Manual Changes - Agilent Technologies 6010A User Manual

Dc autoranging power supply
Hide thumbs Also See for 6010A:
Table of Contents

Advertisement

Section 3 Manual Changes

On page 30 under "Overvoltage Protection", change 107% to 90%.
On page 36 under "Analog Programming", in the 3rd paragraph, change the second sentence to read: "A resistance of 0 to
3.33 K ohms programs the output voltage from 0 to full scale and a resistance of 0 to 4 K ohms programs the output current
from 0 to full scale.".
On page 36 under "Analog Programming" in the 5th paragraph, change the second sentence to read, "A voltage of 0 to 4.25
V programs the output voltage from 0 to full scale and a voltage of 0 to 5 volts programs the output current from 0 to full
scale.".
On page 36 under "Constant Voltage Output, Resistance Control", in the second sentence, change 4000 ohms to 3.33k
ohms.
On page 37 under "Constant Voltage Output, Voltage Control", change "0 to + 5 volts" to "0 to 4.25 volts".
In Figures 3-8 and 3-9, where 5 Vdc, 5 E or 5 appear, change them to read +4.25 Vdc, 4.25E, or 4.25 respectfully.
On page 41 under "Monitor Signals", change "0-5 Volts" to " 0-4.5 Volts for Voltage monitor and 0-5 Volts for current" .
44 Appendix A