Agilent Technologies 6010A User Manual page 13

Dc autoranging power supply
Hide thumbs Also See for 6010A:
Table of Contents

Advertisement

6012B
6015A
0-60 V
0-500 V
0-50 A
0-5 A
1000-1200 W
1000-1050 W
0.01% + 5 mV
0.01% + 40 mV
0.01% + 10 mA
0.03% + 34 mA
0.01% + 3 mV
0.01% + 13 mV
0.01% + 10 mA
0.03% + 17 mA
5
0.005% + 5 mV/40 mV
50 mV/160 mV
1, 4
25 mA/
50 mA
2 ms/3 ms
5 ms/
100 mV/300 mV
200 mV/
6012B
6015A
20 mV
15 mV
20 mA
2.5 mA
20 V, 200 V
2000 V
10 mV, 100 mV
1 V
0.65% + 3.5 counts,
1% + 3.5 counts
0.65% + 3.5 counts
80 ppm + 1mV,
100 ppm + 30 mV
80 ppm + 1mV
200 A
20 A
100 mA
10 mA
0.6% + 4 counts
1% + 4 counts
100 ppm + 2 mA
100 ppm + 7.5 mA
200 V
2000 V
100 mV
1 V
2.5% + 550mV
3% + 1 count
200 ppm + 3 mV
100 ppm + 30 mV
24
24
24 A
24 A
15 A
15 A
14 A
14 A
1450 W
1256 W
80 ppm + 4 mV
100 ppm + 30 mV
100 ppm + 8 mA
100 ppm + 7 mA
0.03 % + 5 mV
0.03% + 40 mV
0.03% + 10 mA
0.03% + 17 mA
90 mV/200 mV
750 mV
300 ms/120 ms (3.4 )
350 ms (250 )
300 ms/ 120 ms
250 ms
2 s/400 ms (3.4 )
600 ms (250 )
3 s/ 35 s (100 )
7 s (100 )
0-64 V
0-535 V
200 mV
1.5 V
0.25% + 550 mV
0.3% + 1.25 V
0.3% + 15 mV
1% + 150 mV
0.36% + 20 mA
0.5% + 100 mA
0.5% + 70 mV
1% + 600 mV
1% + 500 mA
2% + 425 mA
0.3% + 70 mV
0.8% + 600 mV
0.36% + 500 mA
0.7% + 425 mA
50 A
5 A
20 A
5 A
6023A
0-20 V
0-30 A
200-242 W
0.01% + 2 mV
0.01% + 9 mA
0.01% + 1 mV
0 01% + 6 mA
3 mV/30 mV
1, 4
30 mA/
6
1 ms/2 ms
6
50 mV/150 mV
6023A
5 mV
10 mA
20 V, 200 V
10 mV, 100 mV
0.6% + 20 mV, 0.6 +
200mV
75 ppm + 0.25 mV
200 A
100 mA
0.6% + 200 mA
100 ppm + 1.5 mA
200 V
100 mV
2.5% + 250mV
200 ppm + 1 mV
6.0 A
6.5 A
3.8 A
3.6 A
340 W
70 ppm + 0.6 mV
100 ppm + 2 mA
0.02 % + 1 mV
0.03% + 10 mA
5 mV
100 ms (2 )
100 ms
200 ms (2 )
500 ms (50 )
0-23 V
100 mV
0.25% + 250 mV
0.25% + 2 mV
0.3% + 15 mA
0.5% + 12 mV
1% + 110 mA
0.25% + 12 mV
0.3% + 110 mA
30 A
15 A
6028A
0-60 V
0-10 A
200-242 W
0.01% + 3 mV
0 01% + 5 mA
0.01% + 2 mV
0 01% + 2 mA
3 mV/30 mV
1, 4, 7
1, 4
5 mA/
6
1 ms/
6
75 mV/
6028A
15 mV
10 mA
20 V, 200 V
10 mV, 100 mV
0.6% + 20 mV, 0.6 +
200mV
75 ppm + 0.25 mV
200 A
100 mA
0.6% + 70 mA
100 ppm + 1.5 mA
200 V
100 mV
2.5% + 250 mV
200 ppm + 1 mV
6.0 A
6.5 A
3.8 A
3.6 A
325 W
70 ppm + 0.6 mV
100 ppm + 2 mA
0.02% + 2 mV
0.03% + 10 mA
15 mV
150 ms (2 )
120 ms
150 ms (2 )
750 ms (50 )
0-67 V
100 mV
0.25% + 250 mV
0.25% + 2 mV
0.3% + 15 mA
0.5% + 36 mV
1% + 40 mA
0.25% + 36 mV
0.3% + 40 mA
10 A
5 A
NOTES.
1. P-P PARD not specified
2. Initially, for each degree
below 20 C the ripple
increases 2.4 mV/ C.
After load is applied
for 15 minutes, the increase
becomes 1.4 mV/ C.
3. After a five-minute wait.
4. CC PARD is specified for
a 1.2 m (4 feet) length load
lead
5. P-P 75mV (20 Hz to
100MHz
6. 50% change not specified
7. Typical common mode current
1 mA RMS/40 mA P-P
General Information
13

Hide quick links: