Smart Camera Setup - Omron Sysmac F430-F Series Connection Manual

Smart camera
Hide thumbs Also See for Sysmac F430-F Series:
Table of Contents

Advertisement

7.2. Smart Camera Setup

Set up the Smart camera.
Precautions for Correct Use
Use a PC (personal computer) to set the parameters for the smart camera.
Note that there may be some changes required for the PC settings depending on the current
state of PC.
7.2.1.
Install the (AutoVision) software
Install the (AutoVision) software application used for setting up the Smart camera. For
more details on installing the Autovision software, please refer to the "AutoVision Quick
Start Guide" (Z434).
7.2.2.
Set Parameters
Set the parameters for the Smart camera.
Set the IP address of your computer to "192.168.188.100" and its subnet mask to
"255.255.0.0".
1
Connect the RS-232C-I/O 2
Pronge cable (V430-W2-3M) to
the I/O Connecter.
Then connect the V430-W2-3M
I/O connector side to I/O cable
V430-W8-3M.
Connect the 24V and 0V wires
of V430-W8-3M to the 24 VDC
power supply.
* In this document, only the
power supply line of the I/O
cable is connected and
connection confirmed. Be
careful not to short-circuit
any other wires.
* Ground the shielded wire as
needed. For more information
on Grounding, please refer to
the "Smart Camera F430-F
Series User Manual" (Z433) -
"2-7 Grounding and Power"
I/O
Connector
RS-232C-I/O 2 Pronge cable
V430-W2-3M
D-Sub
9 Pin
I/O cable
V430-W8-3M
DC24V
Power
14