General; Maintenance After Initial 50 Hours Of Operation; Maintenance Every 2000 Hours; Fluid Maintenance - Sullair TSR32 User Manual

Industrial air compressor
Table of Contents

Advertisement

6.1

GENERAL

This compressor requires a minimal amount of
inspections
and
maintenance.
situations requiring maintenance, or fault conditions.
6.2
MAINTENANCE AFTER
INITIAL 50 HOURS OF
OPERATION
After the initial 50 hours of operation, a few
maintenance actions are required to clean the
system of any foreign materials. Perform the
following maintenance operations:
1. Clean the return line strainer. Refer to
Maintenance Every 2000 Hours for location.
2. Clean the return line orifice.
6.3
MAINTENANCE EVERY 2000
HOURS
After 2000 hours of operation:
1. Clean the return line strainer. Refer to
Discharge, Receiver and Piping System.
2. Replace the fluid filter element.
6.4

FLUID MAINTENANCE

Drain the receiver tank and change the compressor
fluid using instructions shown in the Lubrication Guide.
6.5

FILTER MAINTENANCE

Refer to Figure 6-1 Replace the fluid filter element
under any of the following conditions, or whichever
occurs first:
1. Every 2000 hours.
indicates high differential pressure.
3. Every fluid change.
Section 6
MAINTENANCE
The
Supervisor
TSR32 USER MANUAL R00
Figure 6-1: Fluid Filter Assembly
1. Filter Head
3. O-ring Seals (I)
5. Drain Plug w/O-ring (I)
(I) Element Replacement Kit P/N 02250139-996
F
F
E
LUID
ILTER
LEMENT
Refer to Figure 6-1.
1. Use a wrench to remove the filter canister.
2. Remove and dispose of filter element properly.
NOTE
Dispose of fluids in accordance with
applicable federal, state and local regula-
tions.
3. Clean gasket seating surface.
4. Apply a light film of fluid to the element seal.
2. Element (I)
4. Bowl
R
EPLACEMENT
39