3-4. Operation Info Mode
3-3.1. Actions
This mode enables the unit to display the accumulated operating time, power On count and each pro-
tection count.
3-3.2. Starting up
While holding down buttons "ZONE2 SOURCE" and "STATUS" simultaneously, press the power button
to turn on the power.
Select the "4. OP INFO" using the "TUNER PRESET CH+ / -" button, then press the "STATUS" button
to confirm.
3-3.3. Operations
Press the "STATUS" button after starting up this device in Operation Info mode.
The following information is displayed in the following order.
(a) Accumulated operating time
L1
Operate
L2
Time:
L3
______H
↑ Time display
"STATUS"
(b) Power On count
L1
Power On
L2
Time:
L3
______
↑ Count display
"STATUS"
(c) DC / ASO Protection count
L1
Protect
L2
DC :___
L3
ASO:___
"STATUS"
(d) Thermal Protection (E) count
L1
Protect
L2
TH E:___
L3
"STATUS"
(e) Current Protection count
L1
Protect
L2
CURRENT:
L3
___
"STATUS"
(Returns to normal display)
141