When the results of check item (36) are "00"
(Detection of 5V is not OK)
Check the +5V voltage. (HDMI SW)
Check item(38).
Check the +5V voltage :
Does "+5V" at the following test point indicate 5V? [N1015/N1016/N1017]
N1017
N1016
N1015
HDMI 3
HDMI 2
HDMI 1
[GAME]
[Blu-ray/DVD]
[CBL/SAT]
+5V
+5V
+5V
YES
HDMI SW [U1024] is faulty.
Replace with a new device.
Recheck from
check item (2).
If it does not work, replace the PCB.
NO
Check for a short circuit in the 5 V line and the 5
V Switch IC [U1025].
If there is no problem, the HDMI SW [U1024] is
faulty.
Replace with a new device.
When the results of check item (37) are
"00 or
(Detection of DDC is not OK.)
Check the DDC line. (HDMI SW)
Check item(39).
Check the DDC LineHPD line :
Are waveforms of "CK" and "DA" observed at the test point near the HDMI input terminal
N1016/N1017]?
N1017
N1016
N1015
HDMI 3
HDMI 2
HDMI 1
[GAME]
[Blu-ray/DVD]
[CBL/SAT]
DDCSCK
DDCSDA
YES
HDMI SW [U1024] is faulty.
Replace with a new device.
Recheck from
check item (2).
If it does not work, replace the PCB.
98
04"
[N1015/
less than 100KHz
5V
5V
This diagram shows an example of the DDC commu-
nication waveform.
-The high level voltage is 5V.
-The frequency of the DDC CLK is 100KHz or less.
Check at each test point.
Voltage scale:2.0V/div
Time scale:40us/div
NO
Check for a short circuit in the DDC line.
If there is no problem, the HDMI SW [U1024] is
faulty.
Replace with a new device.