Marantz SR-19EX Service Manual page 38

Hide thumbs Also See for SR-19EX:
Table of Contents

Advertisement

10. ALIGNMENT PROCEDURES
1. AM IF Adjustment
Input Signal Source
Step
Connection
Signal generator output to
1
transmission *loop antenna.
(*:Standard required loop)
REMARK: For receiving antenna, the adapted one is available.
This adjustment is not necessary normally, because the coil LA06 is preset by the original supplier.
It is necessary when the incorrect usable sense and frequency response.
2. AM Tracking Adjustment
**Input Signal Source
Step
Connection
Signal generator output to
1
transmission *loop antenna.
(*:Standard required loop)
2
3
Repeat step 1 and 2 until sensitivity be maximized.
3. AM auto stop Adjustment
Input Signal Source
Step
Connection
Signal generator output to
1
transmission *loop antenna.
(*:Standard required loop)
2
4. FM MONO. Distortion Adjustment
Input Signal Source
Step
Connection
Signal generator output to
1
FM antenna terminal. (75 )
Signal
Source Signal Output
Frequency
Level and Modulation
999 kHz
u
(C, K, S)
Level 300 V/m (50dB/m)
1000 kHz
Mod. 400 Hz 30%
(U)
Signal
Source Signal Output
Frequency
Level and Modulation
603 kHz
(C, K, S)
Level 300 - 400 V/m
600 kHz
Mod. 400 Hz 30%
(U)
1404 kHz
(C, K, S)
Level 300 - 400 V/m
1400 kHz
Mod. 400 Hz 30%
(U)
Signal
Source Signal Output
Frequency
Level and Modulation
999 kHz
500 V/m (54 dB/m)
u
(C, K, S)
1000 kHz
(U)
1000 V/m (60 dB/m)
u
Signal
Source Signal Output
Frequency
Level and Modulation
u
500 V (54 dB)
MONO 1 kHz /
98 MHz
Dev.40kHz 53.3% (C, K, S)
(C, K, S, U)
MONO 1 kHz /
Dev. 75 kHz 100%
64
Reception
Adjustment
Frequency
Tuning point
Reception
Adjustment
Frequency
603 kHz
u
(C, K, S)
600 kHz
(U)
1404 kHz
u
(C, K, S)
1400 kHz
(U)
Reception
Adjustment
Frequency
999 kHz
(C, K, S)
1000 kHz
(U)
AUTO
Only Confirm
SCAN
Reception
Adjustment
Frequency
98 MHz
(P2)
(U)
Adjustment
Point
Value
Output level
(L or R)
LA06
Maximum
at TAPE-OUT
Adjustment
Point
Value
Output level
(L or R)
LA01
Maximum
at TAPE-OUT
Output level
(L or R)
CA01
Maximum
at TAPE-OUT
Adjustment
Point
Value
"TUNED"
RA11
indicate on FLD
"TUNED"
indicate on FLD
Adjustment
Point
Value
Distortion level
L201
Minimum
at TAPE-OUT

Advertisement