Sony ILME-FR7 Manual page 7

Interchangeable lens digital camera
Hide thumbs Also See for ILME-FR7:
Table of Contents

Advertisement

− CAM_VersionInq
Returns information on the VISCA interface.
CAM_VersionInq
X = 1 (fixed) for VISCA over IP
Y = 9 (fixed) for VISCA over IP
GGGG = Vendor ID
0001: Sony
HHHH = Model ID
051E: ILME-FR7/FR7K
JJJJ = ROM revision
KK = Maximum socket # (02)
• Control command
The following are stored on the payload division of the control command.
Name
Value
RESET
0x01
ERROR
0x0Fpp
• Control reply
The following are stored on the payload division of the reply for the control command.
Message
Value
ACK
0x01
Inquiry Packet
8X 09 00 02 FF
Description
Resets the sequence number to 0.
The value that was set as the sequence number is ignored.
pp=01: Abnormality in the sequence number.
pp=02: Abnormality in the message (message type).
Description
Reply for RESET.
Reply Packet
Y0 50 GG GG HH HH JJ JJ KK FF