INTRODUCTION

The ENH4X is a horizontal, multi--use furnace coil (see
Figure 1). With the use of field--supplied transition duct,
these furnace coils can also be applied to other similar
horizontal furnaces on the market. The ENH4X is available
in sizes 24 through 60. All models are equipped with a
factory--installed TXV and are used with R--410A refrigerant
systems.
NOTE: Models with tin--plated copper coils, "T" in the 8th
position of the model number, are installed the same as
standard copper coils.

INSTALLATION

This coil is not designed to be installed with furnaces that
measure wider than the coil itself.
These units can be installed in multiple configurations.
Before
installation,
there
requirements that must be considered because poor
installation can negatively alter performance. This section
will briefly discuss those factors.
Ductwork
Coil
Ductwork
Coil
Ductwork
Coil
Figure 2 - - Horizontal- -Left Installation with Filler Plate
2
are
several
performance
Furnace
Airflow
Filler Plate
Furnace
Airflow
Filler Plate
Furnace
Airflow
Filler Plate
A08065
Figure 1 - - Model ENH4X Furnace Coil
Furnace
Airflow
Filler Plate
Furnace
Airflow
Filler Plate
Filler Plate
Furnace
Airflow
Figure 3 - - Horizontal- -Right Installation with Filler Plate
Airflow
Airflow amount and distribution are vital to adequate system
performance. In addition, heat pump applications require
airflow in a particular direction for best performance. See
decal on front of coil for correct direction. Problems that can
be experienced with incorrect airflow include:
S low system performance
S restricted TXV
S frosted coil
S poor humidity control
S water blow--off
When attaching the coil and building the plenum, pay
special attention to the effect these details will have on
airflow. After system start--up, check the cfm to insure that it
is correct. (Generally, the cfm should be 350 to 400 cfm/ton
during normal cooling operation.)
TXV
A thermal expansion valve is utilized in this coil design to
optimize performance and comfort throughout the entire
operating range of the system. Special attention needs to be
taken to the TXV when installing the coil
S Do not overheat valve. Temperatures that exceed 212_F
(100_C) can harm valve performance. Use a wet cloth or
heat sink when brazing.
Shipping Brace
Remove
2 Screws