INSTALLATION INSTRUCTIONS
NOTE: Read the entire instruction manual before starting
the installation.

TABLE OF CONTENTS

SAFETY CONSIDERATIONS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Horizontal Right and Left with Pan Extension
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connect Condensate Drain Line
Model Number Identification
SAFETY CONSIDERATIONS
Improper
installation,
adjustment,
maintenance, or use can cause explosion, fire, electrical
shock or other conditions which may cause death, personal
injury or property damage. Consult a qualified installer,
service agency, or your distributor or branch for information
or assistance. The qualified installer or agency must use
factory--authorized kits or accessories when modifying this
product. Refer to the individual instructions packaged with
the kits or accessories when installing.
Follow all safety codes. Wear safety glasses, protective
clothing and work gloves. Use quenching cloths for brazing
operations. Have fire extinguisher available. Read these
instructions thoroughly and follow all warnings or cautions
attached to the unit. Consult local building codes and the
current editions of the National Electrical Codes (NEC)
NFPA 70.
In Canada, refer to the current editions of the Canadian
Electrical Code CSA C22.1.
Recognize safety information. This is the safety--alert
symbol
. When you see this symbol on the unit and in
instructions or manuals, be alert to the potential for personal
injury.
Understand the signal words DANGER, WARNING and
CAUTION. These words are used with the safety--alert
symbol. DANGER identifies the most serious hazards which
will result in severe personal injury or death. WARNING
signifies hazards which could result in personal injury or
death. CAUTION is used to identify unsafe practices, which
may result in minor personal injury or product and property
damage. NOTE is used to highlight suggestions which will
result in enhanced installation, reliability, or operation.
NOTE: Nitrogen can leak out through the needle pierce
hole in the plugs. This does not indicate a leaking coil nor
warrant return of the coil.
Cased N Coil, Horizontal
ENH4X
PAGE
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
alteration,
service,
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal
injury or death.
1
Before installing, modifying or servicing system, always
2
turn off main power to system. There may be more than
2
one disconnect switch. Lock out and tag switch with a
suitable warning label.
3
3
4
!
4
4
PERSONAL INJURY HAZARD
4
Failure to follow this caution may result in personal
injury.
5
This coil contains Nitrogen precharge of 15 PSIG.
5
Release of this pressure through the center of the
6
rubber plugs is required before removing the plugs.
!
CUT HAZARD
Failure to follow this caution may result in personal
injury.
Sheet metal parts may have sharp edges or burrs. Use
care and wear appropriate protective clothing and
gloves when handling parts.
WARNING
CAUTION
CAUTION
484 01 3700 01 December 2011

Advertisement

loading

Summary of Contents for International comfort products ENH4X

  • Page 1: Table Of Contents

    INSTALLATION INSTRUCTIONS Cased N Coil, Horizontal ENH4X NOTE: Read the entire instruction manual before starting WARNING the installation. TABLE OF CONTENTS ELECTRICAL SHOCK HAZARD PAGE Failure to follow this warning could result in personal injury or death. SAFETY CONSIDERATIONS ......
  • Page 2: Introduction

    INTRODUCTION The ENH4X is a horizontal, multi--use furnace coil (see Shipping Brace Figure 1). With the use of field--supplied transition duct, these furnace coils can also be applied to other similar horizontal furnaces on the market. The ENH4X is available in sizes 24 through 60.
  • Page 3: Furnace Attachment

    Use the following procedure 2. For horizontal--left installation, install pan extension to attach ENH4X horizontal coil to furnace. onto left end of horizontal--condensate pan. Pan NOTE: Remove shipping brace from both ends of casing extension is slotted to fit onto condensate pan edge prior to installation.
  • Page 4: Horizontal Attic

    HORIZONTAL CRAWL SPACE INSTALLATION As an alternate to horizontal attic installation, the ENH4X horizontal coil can be installed in a crawl space by mounting on suitable blocks, pads or by hanging from floor joists. To suspend ENH4X: 1. Cut metal plumbers strap to desired lengths.
  • Page 5: Refrigerant Lines

    REFRIGERANT LINES CONDENSATE DRAIN LINE CONNECTION Refrigerant lines must be configured per local building CAUTION codes and the guidelines outlined in the OD units installation instructions. NOTE: The filter dryer should be placed just before the PROPERTY DAMAGE HAZARD indoor unit. Failure to follow this caution may result in property Connect Refrigerant Liquid and Suction Lines damage.
  • Page 6: Waste Line Connection

    leaks proper condensate drainage. Using secondary drain as explained in the previous note provides further protection against overflow due to a clogged primary drain. NOTE: In applications where return air humidity levels stay at 70% or above for a prolonged period of time, condensation can form on the bottom of pan and drip.
  • Page 7 17 = 17--1/2” 21 = 21” 24 = 24--1/2” BB = 15--1/2” FF = 19.1” JJ = 22.8” LL = 24--1/2” WIDTH Sales Digit (Major Revision) Engineering Digit (Minor Revision) International Comfort Products, LLC Lewisburg, TN 37091 USA 484 01 3700 01...