Test Set-Up And Procedure - JBL ES250P Service Manual

Es series
Hide thumbs Also See for ES250P:
Table of Contents

Advertisement

ES250P
Equipment needed:
Function/signal generator/sweep generator
Integrated Amplifier
Multimeter
Speaker cables
General Unit Function (UUT = Unit Under Test)
1) From the signal generator, connect line level (RCA) cables to the Subwoofer Line Level Input jacks L/R on
the UUT. Use a Y-cable from a mono source if necessary to connect to both inputs.
2) Turn the CROSSOVER control to maximum (150).
3) Turn the LEVEL control on the UUT to completely counterclockwise (MIN).
4) LFE/NORMAL switch should be in NORMAL position.
5) PHASE switch position does not matter.
6) Turn on generator; adjust to 50mV, 50 Hz.
7) Plug in UUT; turn the power switch ON. LED should switch from Red to Green.
8) Turn LEVEL control full clockwise (MAX); immediate and vigorous bass response should be heard and felt
from port tube opening on the bottom.
9) Turn off generator, turn LEVEL control full counterclockwise (MIN), and disconnect RCA cable.
Sweep Function
1) Follow steps 1-8 above, using a sweep generator as a signal source.
2) Sweep generator from 20Hz to 300Hz. Listen to the cabinet and drivers for any rattles, clicks, buzzes or
any other noises. If any unusual noises are heard, remove woofer and test.
Driver Function
1) Remove woofer from cabinet; detach + and - wire clips.
2) Check DC resistance of woofer; it should be 3.6 ohms ±10%
3) Connect a pair of speaker cables to driver terminals. Cables should be connected to an integrated amplifier
fed by a signal generator. Turn on generator and adjust so that speaker level output is 5.0V.
4) Sweep generator from 20Hz to 1kHz. Listen to driver for any rubbing, buzzing, or other unusual noises.
ES250P Test Set Up and Procedure
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents