Control Sequence Of Operation (Standard) - Barcol-Air CERA NXOJOOB Manual

Total ventilation concept for stacked housing co2 controlled fresh outside air ventilation system
Table of Contents

Advertisement

Bathroom
0
0
1
1
signal cable
push-button switch
(wiring by third party)
Remark:
Wiring between the CERA-2 unit and the sensor(s)/switch(es) by third party.
Bathroom
Master Bedroom
push-button switch
0
0
1
1
signal cable
signal cable
signal cable
© 01-2022 | Barcol-Air B.V. | T +31 (0)299 689 300 | www.barcol-air.nl | www.cera-systeem.nl | Changes w/o notice or obligation.
signal cable
Bedroom
Power Outlet
230Vac
BACnet bus
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
CERA
CERA
CERA
CERA
CERA
CERA
CERA - 2
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
CERA
24V
24V
24V
24V
24 V
24 V
24 V
24 V
~
~
~
~
0V
0V
0V
0V
0 V
0 V
0 V
0 V
OP1
OP1
OP1
OP1
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
OP2
OP2
OP2
OP2
N.A. (Optie RV)
N.A. (Optie RV)
OP3
OP3
OP3
OP3
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0V
0V
0V
0V
N.A.
N.A.
N.A.
N.A.
signal cable
CO₂ sensor
CERA-2 Unit
(CERA-S-TCO2)
Power Outlet
BACnet bus
230Vac
CO₂ sensor
CERA2+ Unit
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
CERA - 2
24V
24V
24V
24V
24 V
24 V
24 V
24 V
~
~
~
~
+module
0V
0V
0V
0V
0 V
0 V
0 V
0 V
OP1
OP1
OP1
OP1
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
OP2
OP2
OP2
OP2
N.A. (Optie RV)
N.A. (Optie RV)
OP3
OP3
OP3
OP3
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0V
0V
0V
0V
N.A.
N.A.
N.A.
N.A.
signal cable
CERA-2 | type NXOJOOB
Controls sequence of operation (standard)
CERA - 2
Living room
BACnet bus
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
- -
2 2 2 2
24V
24V
24V
24V
24 V
24 V
24 V
24 V
0V
0V
0V
0V
0 V
0 V
0 V
0 V
OP1
OP1
OP1
OP1
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
OP2
OP2
OP2
OP2
N.A. (Optie RV)
N.A. (Optie RV)
OP3
OP3
OP3
OP3
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0V
0V
0V
0V
N.A.
N.A.
N.A.
N.A.
signal cable
CO₂ sensor
(CERA-S-TCO2)
CERA2+
Living room
BACnet bus
CO₂ sensor
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
CERA-S-TCO2
24V
24V
24V
24V
24 V
24 V
24 V
24 V
~
~
~
~
0V
0V
0V
0V
0 V
0 V
0 V
0 V
OP1
OP1
OP1
OP1
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
0-5 V = 0...+40° C
OP2
OP2
OP2
OP2
N.A. (Optie RV)
N.A. (Optie RV)
OP3
OP3
OP3
OP3
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0-5 V = 0-2000 ppm
0V
0V
0V
0V
N.A.
N.A.
N.A.
N.A.
signal cable
Kitchen
~
~
~
~
0
0
signal cable
push-button switch
(wiring by third party)
Kitchen
push-button switch
0
0
signal cable
signal cable
TYPE CERA-2
1
1
1
1
15