CERA-2 | type NXOJOOB
TYPE CERA-2

Performance data

Sound data (pressure drop ∆ 100 Pa)
Data referring to inlet‐spigot
Model
Air Volume
m/s
l/s
CFM
m³/h
2
23
50
4
47
99
168
125
6
70
149
253
8
94
198
337
10
117
248
421
2
39
82
139
4
77
164
279
160
6
116
246
418
8
155
328
558
10
194
410
697
2
61
129
219
4
122
258
439
200
6
183
388
658
8
244
517
878
10
305
646
1097
Sound data (pressure drop ∆ 150 Pa)
Data referring to inlet‐spigot
Model
Air Volume
m/s
l/s
CFM
m³/h
2
23
50
4
47
99
168
125
6
70
149
253
8
94
198
337
10
117
248
421
2
39
82
139
4
77
164
279
160
6
116
246
418
8
155
328
558
10
194
410
697
2
61
129
219
4
122
258
439
200
6
183
388
658
8
244
517
878
10
305
646
1097
Additional sound absorption of Sonodec acoustic hose (1 meter)
Hz
125
250
500
dB
17
22
22
1. Sound data is determined in a reverberation
room at an independent sound laboratory,
according to ISO 3741 en ISO 5135
standards.
2. Lw/Oct. (re. 1pW) are sound power levels
for discharge and radiated sound. Values
< 17 dB are indicated by "-".
3. The values for insertion loss L
include end reflection.
14
Discharge sound (supply)
Lw in dB/Oct. (re 1pW)
min.
ΔPs
Pa
dB
84
10
63
57
52
41
29
26
29
66
60
55
46
35
31
56
68
61
56
49
39
34
88
69
62
57
50
42
36
125
X
X
X
X
X
X
5
62
59
51
43
36
34
18
66
63
56
50
43
39
41
69
65
58
53
47
43
74
71
66
60
56
50
45
116
X
X
X
X
X
X
6
62
55
50
43
39
32
22
67
61
54
49
45
39
50
70
65
57
52
48
42
89
72
67
59
54
50
45
139
X
X
X
X
X
X
Discharge sound (supply)
Lw in dB/Oct. (re 1pW)
min.
ΔPs
Pa
dB
84
10
65
60
57
45
33
31
29
70
64
60
50
40
36
56
73
66
61
53
44
39
88
75
68
63
56
46
42
125
77
69
64
57
48
43
5
64
63
56
47
40
39
18
70
66
60
53
47
44
41
74
69
62
57
51
47
74
76
70
64
59
53
49
116
78
71
65
61
55
50
6
65
60
54
47
44
39
22
70
66
59
52
49
44
50
74
69
61
56
52
47
89
76
71
63
58
54
49
139
78
73
64
59
56
51
1000
2000
4000
27
19
14
4. dB(A), NC and NR index values are sound
pressure levels. Sound pressure levels
< 20 are indicated by "--".
5. The sound pressure levels for discharge
sound include the values for an acoustic
hose in accordance with table 1.
6. Lp values are including a room absorption
do not
of 10 dB/Oct.
w
© 01-2022 | Barcol-Air B.V. | T +31 (0)299 689 300 | www.barcol-air.nl | www.cera-systeem.nl | Changes w/o notice or obligation.
Discharge sound (return)
Lp values
Lw in dB/Oct. (re 1pW)
dB
23
57
49
43
35
29
26
63
55
48
42
36
28
20
22
67
58
51
46
40
29
22
24
70
61
53
49
43
X
X
X
X
X
X
X
X
23
49
45
43
35
27
28
21
58
54
50
44
37
30
22
24
64
59
55
49
43
32
24
26
68
63
58
53
47
X
X
X
X
X
X
X
X
22
52
45
40
34
30
27
21
56
51
45
39
34
31
22
24
59
54
48
42
37
33
25
27
61
56
50
45
39
X
X
X
X
X
X
X
X
Discharge sound (return)
Lp values
Lw in dB/Oct. (re 1pW)
dB
26
20
57
51
46
40
35
30
22
24
66
58
52
46
41
33
26
28
71
62
55
50
44
35
29
30
74
65
57
52
47
36
31
32
77
67
59
54
49
27
20
51
47
45
39
34
32
23
25
61
56
52
47
42
34
27
28
66
62
57
52
46
37
30
31
70
65
60
55
49
38
32
33
73
68
63
57
52
26
20
52
46
43
38
35
31
23
25
58
53
49
44
39
34
27
28
62
57
52
47
42
37
30
31
65
60
54
49
43
38
32
33
67
62
56
50
45
Radiated sound
Lp values
Lw in dB/Oct. (re 1pW)
dB
18
29
19
27
22
32
27
22
21
32
26
21
34
32
27
24
36
29
22
24
35
35
30
27
X
X
X
X
X
X
X
X
17
27
24
29
20
32
31
26
22
36
26
34
36
31
26
41
29
20
23
36
40
35
29
X
X
X
X
X
X
X
X
22
27
20
27
32
30
24
21
30
34
36
29
24
32
22
36
39
33
27
X
X
X
X
X
X
X
X
Radiated sound
Lp values
Lw in dB/Oct. (re 1pW)
dB
23
30
20
18
31
25
35
29
24
24
36
29
23
25
37
34
29
27
40
33
27
29
39
37
33
30
42
35
31
32
41
40
36
32
25
30
25
20
18
34
23
35
32
28
24
40
28
21
37
37
33
28
44
32
23
25
39
40
37
31
47
34
26
28
40
43
39
33
28
30
22
18
18
33
34
31
26
23
35
23
37
37
31
26
37
26
38
40
35
29
39
28
20
39
43
37
30
7. ∆p
is the static pressure loss in the CERA
is the static pressure loss in the CERA
s
s
s
unit with the damper fully open.
8. Where an "X" is shown in the table,
the unit's own resistance is > 100 Pa,
which means sound levels at 100 Pa
are not available.
9. For non standard applications and/or
selections please contact our technical staff .
Lp values
19
22
17
22
X
X
X
X
X
17
17
20
22
22
23
25
24
27
X
X
X
X
X
19
19
22
21
22
24
22
25
X
X
X
X
X
Lp values
19
23
19
22
25
22
25
28
23
28
18
21
22
21
24
24
25
27
26
28
29
28
30
18
22
22
20
25
24
24
27
26
27
29
27
29