IOM 13
Reference Number:

Refit / Refurbishment Method

STEP 1:
Before any refit or refurbishment is carried out, ensure the pipeline
is depressurised.
Turn the handwheel anti-clockwise to open the valve.
Remove the handwheel.
STEP 2:
Prior to removing the cover capscrews, unlock the gland lock
(clockwise) and unlock the gland nut (anti-clockwise).
Do not remove these nuts yet - leave loose.
STEP 3:
Remove the 8 capscrews from the cover
STEP 4:
Remove cover and plate from body.