Cell Maintenance; Cell Cleaning; Cleaning With Optional Cleaning Cap - Intermatic PE25K120V Installation Manual

Salt chlorine generator
Hide thumbs Also See for PE25K120V:
Table of Contents

Advertisement

Page 15
Section 6. Maintenance/Cleaning
Maintaining your I-Pure System requires minimal
work but will maximize the performance and life of the
system.
Section 6.1 Cell Maintenance
Our clear Cell allows for easy regular inspections for calcium build up. Visually check the Cell
periodically, and clean it as necessary (1 to 2 times per year). Advanced self-cleaning technologies,
including reverse polarization and IBT™ help the cell stay cleaner than other self-cleaning cells, but
minimal biannual cleanings are required.
Section 6.2 Cell Cleaning
Do Not use metal or other hard objects to clean the cell as this could scratch the precious coating on the
plates and void the warranty.
Always add acid to water, NOT water to acid
Diluted Muriatic Acid solution = 10 parts water to 1 part acid
Note: Follow the instructions of the acid manufacturer.

Cleaning With Optional Cleaning Cap

1.
Remove the cell from the line by undoing the
barrel unions from the cell ends. There is no
need to remove the wire connections when
using the cleaning cap.
2.
Remove the black o-rings on the ends of the
Cell. (Fig. 1)
3.
Attach the Cell Cleaning Cap to one end of
Cell. (Fig. 2)
NOTE
DANGER
NOTE:
Pool water should be tested bi-monthly.
Fig. 1
Fig. 2