Ductwork And Filter - International comfort products H8UH5050B12C2 Installation Instructions Manual

80+ single stage gas furnace
Table of Contents

Advertisement

Electrical Connections
Figure 17
220V. 50Hz.
W
BK
G
Connection
Box
Ground
Thermostat
Y
G
R
W
G
W
R
C
Y
Low Voltage
Terminal Board
NOTE: 220 VAC/50Hz/single--phase
Operating voltage range*: 242 max, 198 min.
* Permissible limits of voltage at which furnace will operate
satisfactorily

10. Ductwork and Filter

!
CARBON MONOXIDE POISONING HAZARD.
Failure to follow this warning could result in
personal injury or death.
Do NOT draw return air from inside a closet or utility
room where furnace is located. Return air duct
MUST be sealed to furnace casing.
WARNING
!
FIRE HAZARD.
Failure to follow this warning could result in
personal injury, death and/or property damage.
Place furnace on noncombustible subbase on
downflow applications, unless installing on
non- -combustible flooring.
Duct Connections
This furnace may be installed in only a bottom or side return
application. Return air duct connection through the back of the
furnace is NOT allowed.
Upflow ONLY: Side return--air duct connections can be made by
cutting out the embossed area shown in Figure 19. A plugged hole
is provided at each furnace side duct location to help start cutting
441 01 5003 01
Furnace Control
The furnace control is preset at the factory with ON delay of 36
seconds in the heating mode. The blower OFF timing is preset at
168 seconds. If desired, the fan OFF delay can be reset to obtain
the longest delay times while still maintaining comfort levels. See
"Furnace Wiring Diagram".
Furnace Control Fuse
The 24V circuit contains a 5--amp, automotive--type fuse located on
furnace control. (See Figure 18) Any electrical shorts of 24V wiring
during installation, service, or maintenance may cause fuse to blow.
If fuse replacement is required, use only a fuse of identical size (5
amp.).
Figure 18
Jumper
24 VAC
HUM
the opening. Side duct connections are NOT permitted in horizontal
flow applications.
Figure 19
Upflow and Horizontal Flow: Bottom return--air duct connections
can be made by removing the knockout panel in the furnace base.
Do NOT remove knock-out except for a bottom return--air duct
connection.
Duct Design
Design and install air distribution system to comply with Air
Conditioning Contractors of America manuals or other approved
methods that conform to local codes and good trade practices.
Specifications are subject to change without notice
Control Connections
FUSE
Cut out Side Return Air Opening
Diagnostic Light
HUM
25--24--98
Cut out
Starting
Hole
19