Intermatic EI20 Install And Operation Instructions

Digital 7-day wall switch timer

Advertisement

MODEL EI20
DIGITAL 7-DAY WALL SWITCH TIMER
INSTALLATION AND OPERATING
INSTRUCTIONS
Features
• Automatic or manual operation. Push the clear cover/switch to switch On or Off at any time.
• Program up to 6 On/Off setting pairs (12 automatic switch settings).
• Each setting time can be once a week, every day, every weekday, or only on weekends.
• LCD Digital clock and readout.
• Random feature automatically varies switching times for a "lived-in" look.
• One AAA Alkaline battery keeps time, operates timer, and keeps the program for up to 1
1
/
2
utility power.
• Can be used for flood (PAR) and compact fluorescent lamps and dimmers.
• Unique "hard contact" output switch allows timer to control most 120 VAC loads.
Also controls many loads 12 to 277 VAC and 12 to 28 Volts DC.
Refer to product label for maximum ratings for various voltages and load types.
Introduction
The timer can replace your regular or 3-way light switch (where two switches control the same light) to control
lights for security, or can control an outlet to switch most 120VAC loads up to the maximum rating on the
timer label. The timer can control incandescent lights, fluorescent lights, flood lights (PAR lamps), stereos, or
appliances such as an air conditioner. The timer can also control many loads 12 to 277 VAC and 12 to 28 Volts
DC. Timer may not be used with lighted switches.
You will need to use a Decorator style wall plate with this timer (not supplied).
The installation instructions on this page are for replacing a light switch (or 3-way light switch) with the timer. See
"Other Installations" on the next page for wiring diagrams for new construction, switching from 3 or more loca-
tions, or using the timer with a dimmer.
Installation Instructions - Single Switch or 3-way - to replace an existing switch:
1.TURN OFF POWER by REMOVING FUSE or turning
7/16"
the CIRCUIT BREAKER OFF.
2. Remove the existing wall switch.
Prepare the ends of the building wiring as shown.
Trim building wires bare to 7/16".
Single switch:
BLACK WIRE
3. Connect one of the building wires to the black wire
from the timer, using the wire nuts provided. Connect
the other building wire to the blue wire from the timer.
THE RED TIMER WIRE IS NOT USED FOR SINGLE
SWITCH INSTALLATIONS. Cap the red wire with a
BLUE WIRE
wire nut.
BE SURE THAT ALL THE WIRE NUTS ARE SECURE.
RED WIRE
(Capped, Not Connected)
3-way switch: (See "Other Installations" to use a dimmer or if switching from 3 or more locations)
3a. A three way switch has three wires connected to it. One of the wires is "common" (the terminal has a dif-
ferent colored screw or there are markings on the old switch). Connect the Black wire from the timer to the
common wire. Connect the other two wires to the Blue and Red wires from the timer (it doesn't matter which
goes to which.)
RED WIRE
COMMON
BLUE WIRE
REMOTE
WIRE FROM
3-WAY
"COMMON" OF
SWITCH
OLD SWITCH
BLACK WIRE
3b. Identify the "common" terminal at the other (remote 3-way) switch. Connect the supplied jumper wire from
the common terminal to one of the other two terminals of the switch.
(If the light does not turn on when you get to step 9, turn power off at the fuse or circuit breaker and switch the
jumper wire to the other terminal.)
4.Tuck the wires into the wall box leaving room for the timer.
5. Using the screws provided, mount the timer to the wall box then install the wall plate.
Battery (If not supplied with unit.)
6. Release battery holder with flat screwdriver at notch (6a) and pull straight out. Uses a standard AAA alkaline
battery. Set the battery in the battery holder (+ towards front of timer). Tuck battery under plastic tab of holder.
Insert battery holder so it clicks into place.
7. Pull at notch at top edge to remove the clear/cover switch so you can
use the programming buttons.
7
8. To stop the flashing display and turn switch to OFF: Push RESET button;
MAN
AM
Push MODE so CLK is displayed at the upper left; push H+ to stop the
MO
ON
flashing display; push MODE twice so MAN is displayed at the upper
right; push ON/OFF EVENT so display at upper right says OFF (you may
MODE
ON/OFF
RESET
EVENT
hear the timer motor run and a clicking sound).
6b
H+
DAY
M+
9. Your timer is now ready for use. Return the power to the circuit at the
6a
service panel.
Battery
Holder
Battery Replacement
The 1.5 VOLT alkaline battery should operate your timer for 1
1
/
years or more under typical conditions. High
2
or low temperature or frequent use of the manual pushbutton or the 3-way switch will reduce the battery life.
Replace the battery when the digital display is dim, the message 'lobAt' (Meaning LOW BATTERY) is displayed,
or if the timer fails to operate. Press any button to clear the 'lobAt' message. The timer has built-in memory
protection providing at least 15 seconds to change a weak battery without losing your settings. You do not
need to turn off the load or the power in order to replace the battery, however, do not attempt to switch the
timer on or off while the battery is out or your settings will be lost and the timer will need to be reset.
Programming and Operating Instructions
Introduction to Operation and Programming:
The timer is a programmable switch.
At any time you can push the clear cover/switch to manually turn the switch ON or OFF, unless selected mode is
CLK or PGM.
You can program up to 12 ON/OFF EVENTS; times when the timer automatically switches the connected lights
(or other electrical devices) ON or OFF (up to 6 ON events and 6 OFF events). An EVENT can be set to switch at:
• any specific time, and day of the week,
• a specific time every day,
• a specific time on weekdays, or
• a specific time on weekends.
See Installation Instructions first if your timer is not already installed, or if the AAA Alkaline battery is not
installed.
Manual Override
Works like a light switch. Push and release the clear cover/switch
(area over buttons) to switch ON or OFF. Or switch ON and OFF
using the remote switch(es) in multi-switch installations.
Works in AUTO, AUTO RAND or MAN modes.
AUTO RAND
You hear a motor/clicking sound.
PM
WE
ON
ON/OFF display changes.
The program in AUTO or AUTO RAND remains; it automat-
ON/OFF
MODE
RESET
EVENT
ically switches ON or OFF at next programmed time.
DAY
H+
M+
PUSH ON/OFF
CAUTION: This timer should not be used in precision timing applications where
inaccurate timing could have dangerous consequences (i.e., sun lamps, sauna, etc.)
Controls and Displays
Cover/Switch
The clear cover/switch is the manual ON/OFF control.
1. Pull at notch at top edge to remove cover so you can
use the programming buttons.
To replace cover/switch:
2. Set bottom in first.
1
3. Click in the top.
MAN
AM
To remove battery:
MO
ON
4. Grasp holder at side bumps
MODE
ON/OFF
RESET
(4a,4b) and pull straight out.
EVENT
DAY
H+
M+
To re-install battery:
5. Place battery in holder with "+"
end towards front of timer. Insert
battery and holder into timer.
Push at (5) so it clicks
years, even without
into place.
Battery Holder
Push Buttons:
RESET button
Recessed so you don't push it accidentally.
ON/OFF
Push and release to reset:
MODE
RESET
RESET
EVENT
When you press RESET:
The mode switches to MAN.
DAY
H+
M+
The switch is set to ON.
The clock is set to MO 12:00 AM and flashes.
All programmed ON or OFF times are set to null
(at null, no switching occurs, clock displays -:--).
(After pushing RESET, you must set the clock then set the
ON/OFF times.)
If NoOp appears in display, push battery cover in until you
hear a click. Push RESET button to clear display. Proceed
with programming.
MODE button
ON/OFF
Push and release to change the mode (upper line of the display).
MODE
RESET
EVENT
CLK mode - To set or change the time.
MODE
PGM mode - To set, review or change programmed ON/OFF times.
DAY
H+
M+
AUTO mode - Programmed ON/OFF times work. Manual
switching works.
AUTO RAND mode - Programmed ON/OFF times work and
are randomly offset up to 15 minutes. Manual switching works.
MAN mode - Only manual switching works. Programmed
ON/OFF times remain in memory.
The Mode button skips the AUTO modes if the time of day
and/or the ON/OFF times have not been set.
DAY button
Function depends on the mode:
ON/OFF
MODE
RESET
EVENT
CLK mode - Push and release to cycle through the days of the
DAY
week: MO,TU,WE,TH, FR, SA, SU. Push and hold to cycle quickly.
DAY
H+
M+
PGM mode - Push and release to cycle through all week, week-
days, weekend, individual days of the week and null:
MO TU WE TH FR SA SU (all displayed at once is all week)
MO TU WE TH FR (all displayed at once is weekdays)
SA SU (displayed is weekend)
MO,TU,WE,TH, FR, SA, and SU (are individual days)
MOVE
-:-- (on clock display is the null setting)
JUMPER WIRE
Use null to cancel an unwanted ON or OFF setting. The DAY but-
TO OTHER
ton does nothing in AUTO, AUTO RAND or MAN modes.
TERMINAL
IF THIS
H+ (hour) button
SWITCH
Works in CLK and PGM modes.
DOES NOT
ON/OFF
MODE
RESET
EVENT
TURN LIGHT
Push and release to cycle forward through the hours of the day.
H+
ON
Push and hold to cycle quickly.
DAY
H+
M+
AM and PM automatically switch at 12.
If you pass the correct hour, push and hold to cycle around again.
M+ (minute) button
MODE
ON/OFF
RESET
Works in CLK and PGM modes.
EVENT
Push and release to cycle forward through the minutes.
M+
Push and hold to cycle quickly.
H+
DAY
M+
If you pass the correct minute, push and hold to cycle around
again.
ON/OFF/EVENT button
MODE
ON/OFF
Function depends on the mode:
RESET
EVENT
CLK mode - ON/OFF EVENT button does nothing.
ON/OFF
PGM mode - Switches in order through the 12 programmable
EVENT
H+
DAY
M+
events 1
, 1
ON
OFF
6
, and 6
.
ON
OFF
AUTO mode - Manually turns switch on or off.
AUTO RAND mode - Manually turns switch on or off.
MAN mode - Manually turns switch on or off.
How to set or change the clock
1. Remove the clear cover/switch.
2. Push and release MODE button until CLK is displayed (2a).
3. Push and release DAY button until correct day of week is displayed (3a).
4. Push and release H+ button until hour and AM/PM are correct (4a).
5. Push and release M+ button until minutes are correct (5a).
6. Push and release MODE button to choose AUTO, AUTO RAND or MAN.
7. Replace clear cover/switch.
8. Push and release clear cover/switch to switch load ON or OFF if
necessary.
How to set, change, or review ON/OFF times
1. Remove clear cover/switch.
2. Push and release MODE button until PGM is displayed (2a).
[at event 1
]
ON
3. If necessary, push and release ON/OFF/EVENT button until event to
set/change is displayed (3a), or push the ON/OFF/EVENT pushbutton
repeatedly to review all the ON/OFF times.
4. Push and release DAY button until desired day or group of days is displayed
(4a), or push and release the DAY button until "-:--" is displayed, if you would
like to cancel this ON or OFF time.
5. Push and release H+ button until desired event hour and AM/PM are
displayed (5a).
6. Push and release M+ button until desired minutes are displayed (6a).
7. Push and release ON/OFF/EVENT button to choose the next event to set
or change (7a).
8. Push and release MODE button to choose AUTO, AUTO RAND, or MAN.
9. Replace clear cover/switch.
10. Push and release clear cover/switch to switch load ON or OFF if
necessary.
LOAD MAINTENANCE
WARNING1 DO NOT USE THE TIMER TO TURN OFF POWER FOR MAINTENANCE (repairs, removing broken
bulbs, etc.). ALWAYS TURN POWER OFF AT THE SERVICE PANEL BY REMOVING A FUSE OR SWITCHING OFF
A CIRCUIT BREAKER BEFORE DOING ANY CIRCUIT REPAIRS.
Error Messages
The 'lobAt' message means the battery is low and needs to be replaced. Uses one standard AAA alkaline battery.
The display is 'noOp' (Meaning no Operation) if the timer fails to operate. This can happen in very cold tempera-
tures. Normal timer operation should resume at normal temperatures. Press any button to clear the message(s).
If the 'noOp' remains at normal temperatures with a fresh battery, timer needs repair.
Other Installations
MULTISWITCH APPLICATIONS USING THE ELECTRONIC TIMER ARE WIRED DIFFERENTLY
THAN WHEN USING CONVENTIONAL TOGGLE SWITCHES.
INSTRUCTIONS CAREFULLY.
3
Multiple timers may be mounted in adjacent junction box slots.
No derating is required for multiple timers.
MAN
AM
ON
MO
Wiring diagram, 2 switch installation (3-way):
ON/OFF
MODE
RESET
EVENT
4a
4b
DAY
H+
M+
2
BLACK
5
LINE
TIMER
NOTE: For new construction or to replace a dimmer switch, a lighted switch, or a 3-way switch without screw
terminals, a single pole switch can be used at the remote location, as shown below.
Wiring diagram, 2 switch installation (3-way) using a single pole remote switch:
BLACK
LINE
Wiring diagram, 3 switch installation:
For 3 or more switch operation, AN ADDITIONAL WIRE MUST BE ADDED between the load and the timer.
The jumper wire is not required for these applications.
BLACK
LINE
TIMER
For existing 3 switch installations replace one 3-way switch with the timer and replace the 4-way switch with a
3-way switch.
SYMPTOM
Timer does not operate, display is dim, blank or unreadable, dis-
play shows nonsense or 'lobAt', or timer operates erratically.
Timer does not switch but display is normal.
Timer works manually but does not follow scheduled program.
Timer won't enter the AUTO or AUTO RAND modes when
MODE button is pushed.
Timer switches at incorrect times or skips some switching
times.
Load state doesn't match programmed state immediately after
, 2
, 2
, 3
, 3
, 4
, 4
, 5
, 5
,
ON
OFF
ON
OFF
ON
OFF
ON
OFF
programming the time or schedule.
Display shows 'no Op'.
2a
CLK
5a
4a
PM
WE
ON
3a
MODE
ON/OFF
RESET
EVENT
Timer operates, but light doesn't come on in dimmer applica-
2,6
DAY
H+
M+
tions.
3
4
5
Load only operates when the remote (3-way) switch is in one
position or timer ignores the remote switch.
Timer ignores remote (3-way) switch even though it is wired
3a
PGM
correctly.
2a
3, 7
ON
MODE
ON/OFF
RESET
EVENT
Load turns off immediately after being turned on.
2, 8
DAY
H+
M+
4
Battery holder is difficult to snap in place
6
5
6a
5a
7a
PGM
OFF
PM
MO TU WE TH FR
4a
(Example)
If within one (1) year from date of purchase, this product fails due to a defect in materials or workmanship, Intermatic Incorporated will repair or replace it free of charge.
The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping; (b) units which have been subject to unauthorized repair, opened, taken apart; (c) units not used in accor-
dance with directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific
legal rights, and you may have other rights which vary from state to state.
This warranty service is available by either: a) returning the product to the dealer from whom the product was purchased or (b) mailing postage prepaid to the authorized service station listed below.
Be sure to wrap the product securely when mailing to avoid shipping damage. This warranty is made by Intermatic Incorporated/After Sales Service/7777 Winn Rd., Spring Grove, IL 60081-9698/815-675-
7000 http://www.intermatic.com
4 or more switch installation:
For 4 or more switch installations use the preceding 3 switch installation diagram and wire 4-way switches
READ THE FOLLOWING
between the two 3-way switches.
Note:THE REMOTE SWITCH(ES) MAY NOT FUNCTION RELIABLY WHEN THE ACCUMULATED WIRE
LENGTH TO THE REMOTE SWITCH(ES) EXCEEDS 30 FEET OR IF THE WIRING TO THE REMOTE
SWITCH(ES) IS BURIED UNDERGROUND. Consult factory for details.
Note: Used remote switches from a previous conventional installation may not function reliably with an electronic
timer. Try a brand new remote switch if function is intermittent.
LOAD
JUMPER
BLUE
NEUTRAL
Installations including a Dimmer:
COMMON
RED
3-WAY SWITCH
• The load size and type must not exceed the rating of the dimmer.
(Typically 600 watts, 120 VAC, 60 Hz, incandescent lamps only.)
• If the dimmer is placed in it's 'OFF' position, the timer cannot operate the lights.
• If the dimmer is set too low, the lights may not turn back on under timer control. If necessary, use a
premium quality dimmer that can be turned on at very low settings.
LOAD
LINE
BLUE
NEUTRAL
TIMER
RED
SINGLE POLE SWITCH
Multi-switch installation using a dimmer :
A 3-way dimmer should not be used. If a multi-switch installation is required, use the following diagram.
LINE
ADDITIONAL WIRE
LOAD
BLUE
NEUTRAL
Special applications
RED
Because of it's unique "hard contact" switch feature, your timer may be used for applications not previously possible
for electronic wall timers, such as use with dimmers, use without utility power, use on circuits other than 120 volts,
TWO 3-WAY SWITCHES
controlling relays or contactors, or to control DC voltage (for example in recreational vehicles). See instructions
above for dimmer applications. For DC and high voltage applications please note the reduced load ratings on prod-
uct label. Consult factory for application details.
TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
Battery is worn out, missing or is installed backwards, or timer
was operated while battery was removed.
Timer not in AUTO, AUTO RAND(om), or MAN(ual) mode.
Timer not in AUTO or AUTO RAND(om) mode.
Time of day and/or switching times are not programmed.
Programmed schedule(s) are incorrect.
Timer is in AUTO RAND(om) mode (Varies switching times up
to +/- 15 minutes).
Timer does not "catch up" to the programmed load state. The
load will remain in it's state prior to entering the PGM mode.
The timer will begin following the scheduled program at the
next contrary ON/OFF time.
Mechanism is inoperative.
Dimmer is turned off or is set too low to turn back on or the
bulb is burned out.
Remote switch is wired incorrectly.
Excessive length of wire (greater than 30 feet) or buried wiring
to the remote switch.
Remote switch is defective or worn out.
Remote switch or timer wired incorrectly, excessive length of
wire (greater than 30') or buried wiring to remote switch, or
defective timer.
Battery not seated in holder, holder misaligned, or contact tabs
of holder are bent.
FULL ONE YEAR WARRANTY
LIGHT
BLACK
BLUE
TIMER
DIMMER
NEUTRAL
RED
(Capped, Not Connected)
LIGHT
BLACK
BLUE
TIMER
NEUTRAL
DIMMER
RED
REMOTE SWITCH
REMEDY
Install a fresh AAA size alkaline battery in the direction indicat-
ed. Press RESET button, then reprogram timer.
Use MODE pushbutton to select the desired operating mode.
Use MODE pushbutton to select AUTO or AUTO RAND
Make sure time of day and at least one scheduled activity are
programmed.
Review / Revise ALL 6 ON/OFF switching time pairs by repeat-
edly pushing the ON/OFF/EVENT button while in PGM mode.
Use MODE pushbutton to select AUTO mode.
After entering your schedules or the time, then returning to
the AUTO modes, push the ON/OFF/EVENT button to change
the load state if necessary.
If timer is in a very cold environment, try again when warmer.
If not, and if the battery is good, the timer should be replaced.
Push in battery cover until you hear a click. Push RESET button
to clear display and reprogram the unit.
Replace device if NoOp will not clear from display.
Make sure timer display shows 'ON' then check dimmer oper-
ation at full brightness setting. If timer control is required at
very low brightness settings, use a premium quality dimmer
that can be turned on when set low.
Recheck wiring, especially for the jumper, per "Installation
Instructions - 3-Way Switch" and "Other Installations".
Eliminate condition, replace the buried cable, do without the
remote switch, or consult factory for other options.
Replace remote switch.
If the problem persists with the red wire disconnected or with
a 'remote' switch temporarily connected right at the timer,
replace the defective timer, otherwise try the above remedies.
Line up tabs on bottom of holder with notches in timer hous-
ing when pushing in. Straighten bent contact tabs.
158SS11359