Fault Codes - Fisher & Paykel customer care WH8560P1 Manual

Hide thumbs Also See for customer care WH8560P1:
Table of Contents

Advertisement

479645
6

FAULT CODES

Before replacing any components, always check the harness and connections.
Fault Code Short Description
door open
Door detected as not closed.
no tap
Expected water level not
attained within 8 minutes.
E7:00
Wash Motor Error.
E7:01
Motor Stall Error.
E7:02
Motor Loss of Phase.
E7:03
Motor Over Current.
E7:04
Motor Current Sense Error.
E7:06
Motor Brown Out.
E7:07
Motor Winding Over Temp.
E7:08
Motor Bridge Over Temp.
E7:09
M/C Module Self-Test Error.
Err 10
Heater NTC error which is
displayed at end of program.
Err 12
Water level has exceeded
flood protection level.
Err 37
Pump error.
Err 74
Pressure sensor out of range. Pressure sensor frequency is out of
Reason
Door has been detected as not being
closed 20 sec after program has
been started.
Target water level has not been
reached in the allowed time.
The initial speed of the motor has
been detected as being out of sync.
The motor control module has been
unable to start the motor.
The motor control module has
detected a loss of a of the phase in
the motor.
The motor control module has
detected excessive current.
Motor current sensing circuit is faulty.
The supply voltage level has become
too low to power the motor control
module.
Motor control module has detected
the motor windings over temperature.
Motor control module has detected
that the motor bridge electronics is
over temp
Motor control module during its self-
test routine has detected an error.
The
heater
malfunctioned.
Water level readings found to be
above the flood protection level.
The water level has not changed in 6
minutes.
range
16
NTC
circuit
has

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents