6. POWER AND SIGNAL CONNECTION

6.1 AC Power

Do not connect the fixture to a dimmer system; doing so may damage the fixture.
Make sure the fixture is earthed (grounded). The AC mains supply must be fitted with a
circuit breaker and earth fault switch (ground fault).
Check that the power supply voltage and frequency are corresponding with the AC mains supply
needed by the fixture (check AC mains panel on the fixture).
Before switching on the fixture verify that the tilt lock is released.
Power requirements:
QM575S
QM575W
QME575S 180V ~ 260V AC
QME575W 180V ~ 260V AC
QM700S
QM700W
Power lead Connection.
Wire Colour
Yellow / Green
Blue
Brown

6.2 Fuse replacement

When the fixtures main fuse is blown it can be replaced with a new 31x 6.35mm fuse, 10A/250v.
1. Disconnect the fixture from the mains supply.
2. Open the fuse holder on the fixture power panel by turning the cap counter clockwise using a
Philips head screwdriver.
3. Replace the defective fuse and close the fuse holder by putting the cap back in and turning it
clockwise until it is locked tightly.
4. Connect the mains power again and turn on the fixture to check proper operation.
There are also two fuses on the main PCB board inside the fixture, for how to replace this please
contact your dealer.
QM series manual v3.06
220V ~ 240V AC
220V ~ 240V AC
220V ~ 240V AC
220V ~ 240V AC
50Hz ~ 60Hz
50Hz ~ 60Hz
50Hz ~ 60Hz
50Hz ~ 60Hz
50Hz ~ 60Hz
50Hz ~ 60Hz
Pin connection
AC Earth (ground)
AC Neutral
AC Live
- 7 -
680Watts
680Watts
680Watts
680Watts
850Watts
850Watts
Symbol
N
L
©QMAXZ 2009