Door Handle Replacement - Hussmann Innovator Installation And Service Manual

Reach-in glass door
Hide thumbs Also See for Innovator:
Table of Contents

Advertisement

P/N 0425683F
As shown in Figure 15, this can also be accom-
plished by pushing the magnet across the gap from
the outside with a pencil or other non-heat conduct-
ing material.
Figure 15. Pulling Gasket Into Place
With a Pencil
On doors where the gap is against an end, top, or
bottom mullion, this process can still be done;
however, the heat will need to be directed
between the lip of the mullion and the edge of the
door. It will work in the same fashion but the
back-light shining through and showing on the
mullion will have to be a guide as to the position
of the gasket.
Cool the Gasket
Once the gap is closed, remove the heat and
allow the gasket to cool, undisturbed, for 3 to
5 minutes. As the gasket cools, it will set
permanently in this new shape.
Once the gasket is cool to the touch, open the and
close the door. Verify that the gasket seals. If not,
repeat the process. If the gasket rolls it must be
replaced.
8
Use a soft cloth or paper towels, and a mild soap
and water solution to thoroughly clean the gasket.
Dry the gasket completely with a fresh cloth or
paper towels before closing the door on a clean
door frame.

DOOR HANDLE REPLACEMENT

Carefully pull the
magnetic gasket out
of the groove nearest
the handle to expose
the mounting screws
as shown in
Figure 16. Remove
the screws and
replace the handle.
After reinstalling
screws, carefully
push gasket back
into groove. If need-
ed, use a mild soap
and water solution to
lubricate the gasket.
Clean and dry the
gasket to complete
the door handle
replacement.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM
Mounting Screws
Figure 16. Replacing Door Handle
®