User Information; Non-Glare Glass; Maintenance; Electrical Precautions - Hussmann AB Installation And Operation Manual

Upright meat display case
Hide thumbs Also See for AB:
Table of Contents

Advertisement

Rev. 0408

non-glare Glass

The high optical clarity of this glass is possible due to
special coatings on the glass surface itself. To preserve this
coating and the optical clarity, keep the glass clean.
Windex® or Glass Plus® are the only solutions
recommended to be used to clean the non-glare glass.
The damage to the glass from improper, caustic solutions
is irrepairable.

Electrical Precautions

BEFORE SERVICING
Always disconnect electrical power at the main
disconnect when servicing or replacing any
electrical component.
This includes (but not limited to) Fans, Heaters,
Thermostats and Lights.

Replacing Fluorescent Lamps

Fluorescent lamps are furnished with a shatterproof
protective coating. The same type of lamp with protective
coating must be used if replaced.
This lamp has been treated to resist breakage and must be
replaced with a similarly treated lamp in order to maintain
compliance with NSF Standards.
Contact HUSSMAN Chino for replacement.
1-800-395-9229 X 2131
T-5 Bulbs
Please note: T-5 lights must be turned off and on after bulb
replacement.
Evaporator Fans
The evaporator fans are located at the center front of these
merchandisers directly beneath the display pans. Should
fans or blades need servicing, always replace fan blades
with the raised embossed side of the blade TOWARD THE
MOTOR.
AB
Gravity Coil
Aged Beef
ABG-28-57-8-R
S/C with Paragon Timer

User Information

Maintenance

NSF CODE 4.28.1

Electrical Wiring Diagrams

13
In addition to cleaning the glass with the recommended
product, there are precautions that should be taken when
working and cleaning the inside of the case.
When cleaning the inside of the cases, we
recommend that the glass be fully opened and
covered to prevent solutions from splashing onto the
glass and ruining the coating on the inside.
Copper Coils
The copper coils used in Hussmann merchandisers may
be repaired in the field. Materials are available from local
refrigeration wholesalers.
Hussmann recommends using #15 Sil-Fos for repairs.

Tips and Troubleshooting

Before calling for service, check the following:
1. Check electrical power supply to the equipment for
connection.
2. Check fixture loading. Overstocking case will affect
its proper operation.
3. If frost is collecting on fixture and/or product, check
that Humidity Control is working properly, and that
no outside doors or windows are open-allowing
moisture to enter store.
FOR PROMPT SERVICE
When contacting the factory,
be sure to have the Case Model and Serial
Number handy. This information is on a plate
located on the case itself.
4' ~ 6'
W0050005
W0050006
W0050009

Advertisement