Running A Led Test On The Power Supply; Running A Self-Test On A Power Supply - Cisco SFS InfiniBand Server Switch SFS 7000P Hardware Installation Manual

Cisco systems infiniband server switches installation guide
Hide thumbs Also See for Cisco SFS InfiniBand Server Switch SFS 7000P:
Table of Contents

Advertisement

Chapter 6
Hardware Diagnostic Tests

Running a LED Test on the Power Supply

You can use the LED test to identify a specific power supply by entering these commands:
SFS-7000P> enable
SFS-7000P# config
SFS-7000P(config)# diag power-supply 1
SFS-7000P(config-diag-power-supply-1)# test led
SFS-7000P(config-diag-power-supply-1)# start
SFS-7000P(config-diag-power-supply-1)# stop
SFS-7000P(config-diag-power-supply-1)#

Running a Self-Test on a Power Supply

To perform a diagnostic self-test on a power supply, follow these steps:
Determine the ID of the power supply that you want to diagnose, if you do not already know the number.
Step 1
Enter the show power-supply command.
SFS-7000P# show power-supply
=====================================================================
=====================================================================
ps
---------------------------------------------------------------------
1
2
Specify the type of test (self-test is chosen by default) by entering the diag power-supply id command.
Step 2
SFS-7000P> enable
SFS-7000P# config
SFS-7000P(config)# diag power-supply 2
SFS-7000P(config-diag-power-supply-2)# test self-test
Start the test.
Step 3
SFS-7000P(config-diag-power-supply-2)# start
Display the progress of the test by entering the show diag fan command.
Step 4
SFS-7000P(config-diag-power-supply-2)# exit
SFS-7000P(config)# exit
SFS-7000P# show diagnostic power-supply
======================================================================
======================================================================
Failed=0, Total=1
Display any errors that appear in the result string by entering the show diag fru-error command.
Step 5
SFS-7000P# show diag fru-error
OL-10853-01
type
admin-status
AC
up
AC
up
Diagnostic Tests For Power Supply
module-type : power-supply
module-number : 2
test : self-test
iterations : 1
action : start
result : success
percentage-completed : 100
result-string : Power Supply Self Test Completed, Final report : Passed=1,
Cisco SFS 7000P and SFS 7000D InfiniBand Server Switches Hardware Installation Guide
Power-supply Information
oper-status
utilization
up
n/a
up
15
Running Power Supply Tests
voltage
48
47
6-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sfs 7000dSfs 7000p

Table of Contents